![Simoniz S1750 Owner'S Manual Download Page 11](http://html1.mh-extra.com/html/simoniz/s1750/s1750_owners-manual_1275811011.webp)
10
OPERATING INSTRUCTIONS
Surface Preparation
Before starting any cleaning task it is important to inspect the area for objects which could
create a hazard. Remove objects from the work area which could be tripped over, such as
toys or outdoor furniture. Ensure that all doors and windows are closed tight.
Adjustable Wand
The adjustable wand controls high-pressure/low-pressure and adjusts the spray.
CAUTION
Do not adjust the nozzle while the trigger is squeezed.
High-pressure/Low-pressure
For low-pressure, grasp the collar and slide it away from the gun as shown in. To apply
detergent, the adjustable nozzle must be on the low-pressure setting.
The high-pressure nozzle position is intended for cleaning. To get the high-pressure setting,
grasp collar and slide the collar nozzle towards the gun as shown. Make sure the collar is
pulled completely back to lock the nozzle into the high-pressure position.
Adjusting the Spray
The adjustable spray nozzle can adjust from fan to jet in the high-pressure position only.
The spray is adjusted from jet spray to fan spray by turning the nozzle as shown in.
Note: The pressure of the spray on the surface you are cleaning increases as you move the
wand closer to the surface.
CAUTION
Jet spray adjustment is very aggressive. Do not adjust while spraying. We recom
-
mend that for most cleaning applications a 20º spray angle should be used to avoid
damage to the surface being sprayed.
Turbo Power Wand
The high-pressure turbo nozzle is intended
for maximum cleaning effect. Keep the
spray wand 6–8” (15-20 cm) away from
the cleaning surface at all times.
CAUTION
Do not try to adjust the turbo nozzle.
USING THE ACCESSORIES