background image

INSTALLATION 

1

2

DeScrIpTION

Once plugged to 10000322-039 This Keypad permits the direct control of a load toggling it 

each time that the pushbutton is pressed. It is also possible to control the load using Z-Wave 

devices

DevIce SpecIfIcATION

Device Type                    ON/OFF POWER SWITCH 
Generic Device Type     GENERIC_TYPE_SWITCH_
 

                 BINARY

Specific Device Type     SPECIFIC_TYPE_POWER_
 

                 SWITCH_BINARY

Role Type  

                 ROLE_TYPE_SLAVE_

 

                 ALWAYS_ON 

10000322-039

Identification of 

keypad to be 

plugged

Connections to plug Switch keypad 

10002034-13X

SuppOrTeD cOmmAND cLASSeS

COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V4

COMMAND_CLASS_MANUFACTURER_

SPECIFIC_V2

COMMAND_CLASS_BASIC_V1

COMMAND_CLASS_SWITCH_BINARY_V1

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_ASSOCIATION_GRP_

INFO_V3

COMMAND_CLASS_POWERLEVEL_V1

COMMAND_CLASS_CONFIGURATION_V2

COMMAND_CLASS_METER_V4 (Electric 

measurement; only Watts measurement allowed) 

COMMAND_CLASS_DEVICE_RESET_

LOCALLY_V1

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

Group 1 (Lifeline) -> Name “LIFE”

3

On/Off Report when load state is changed:

- On -> CC Basic, Basic Report, Value 0xFF

- On -> CC Basic, Basic Report, Value 0x00

Instant Power Consumption vary over 10% and is stable almost 2sec

- CC Meter, Meter Report, “Electric meter”, “Consumed”, “Watts”, Size 4, Precision 1, Value (W)

ASSOcIATION GrOupS

Number of Groups

Max. devices in Group 1

Automatic reports to 

Group1

This product can be included and operated in any Z-Wave 
network with other Z-Wave certified devices from other 
manufacturers and/or other applications. All non-battery 
operated nodes within the network will act as repeaters 
regardless of vendor to increase reliability of the network.

Z-WAve cOmpILANce

KeYpAD uSe & feeDBAKS

eveNT

Default State

Press action

(Toggle)

ADD / REMOVE
Network or Asso-
ciation
 
Reset Default

Dysfunction

KeYpAD AcTION

No pressed

Touching detected 
Keypad Pressed
Short Press (T<2sec)
Keypad Release

Hold Press (2sec<T<20sec)
Device Sends a NIF 

Hold Press (20sec<T)
Device removed from Z-Wave ne-
twork and Params are restored to 
default.1

mAIN LeD reSpONSe

LED ON
LED status according Load State

If LED ON, it turns OFF in 5 sec

Blinks with 0,3 sec period

1 Blink with 5 sec period

LED Will blink with 0,1 sec period

1    

Is it recommended to disassociate the keypad from all previous device associations before remove it.

Device is member of a 
Z-Wave Network
Device is Stand Alone 
LED

LED according Config 
Params 1&12 
Blinks with a period of 2 
seconds

NAme

Association LED

Delay ON

Activation TIME

Delay OFF

Behavior of LED in Repose

Lock Input

Reset Default

SIZe BYTe

1

1

 

1

1

2

vALueS

0x00 -> Turns the LED OFF (default)

0xFF -> Turns the LED ON

0x00  

Instantly (default)

0x01-0x7F   1 second (0x01) to 127 seconds (0x7F) 

  

in 1 second resolution. 

0x80-0xFE 1 minute (0x80) to 127 minutes 

 

(0xFE) in 1 minute resolution. 

0x00 -> LED OFF (Default)

0xFF -> LED on at 20% of maximum level

0x00 -> Unlock the direct control of load. (Default) 

0xFF -> Lock the direct control of load.

0x9867 -> Parameters, Groups, and Z-Wave status are restored 

to default. (Write Only)

1

10

11

16

12

13

15

cONfIGurATION

These configurations are not restored to default when device is removed from network.

COMMAND_CLASS_DEVICE_RESET_LOCALLY -> DEVICE_RESET_LOCALLY_NOTIFICATION will be sent to inform 

controller that node has been removed from network, but the device will keep the current configurations.

-  To restore the configurations values, please perform one of these actions:

   ·  Use Command CONFIGURATION SET with default bit to 1 for each configuration parameter.

   ·  Perform Reset Default Action via keypad pressing or Command Reset Default.

Reviews: