User manual - WEIGHT METER SWI-94
”Std”
- answer as quick as possible, no additional delay
” 10c”
” 20c”
” 50c”
”100c”
”200c”
- answer delayed of 10, 20, 50, 100 of 200 chars respectively, where
one character time depends on selected baud rate
In the most cases parameter
”rESP”
should be set to
”Std”
(no additional delay).
Unfortunately for some third party RS-converters
”rESP”
should be adjusted
contains most frequently used values.
”bAud” parameter
“38.4”
“57.6”
“115.2”
”rESP” parameter
“ 10c”
“ 20c”
“ 50c”
Tab.7.2. Settings of ”
rESP
” parameter
7.3.11.
”Edit t”
paramet
er
This parameter allows to change the edition mode of numerical parameters:
”dig”
- the change to “by digit” mode,
”Slid”
- slide change mode.
7.3.12.
”dEFS”
parameter
This setting allows to restore the factory settings of the device. To get the access to
this option special password is required: „5465”, next the device displays acknowledge
question
„SEt?”
. Press
[ENTER]
to acknowledge the restoring of factory settings or
[ESC]
to
cancel.
7.3.13.
”SErv” menu
This menu contains the parameters for authorized service only. To enter this menu
proper service password must be entered. Improper settings can causes of damage of the
device.
39