Simex SLE-42 User Manual Download Page 8

User manual for electronic counters SLE-42 and STH-42

b)

Figure 

4.4. 

Rear terminals description:

a) version with dry contact/OC/NPN input

b) version with wide-range voltage input

4.4. 

 

 MAINTENANCE

 

 

The   unit   (except   battery)   does   not   have   any   internal   replaceable   or   adjustable  

components available to the user. Pay attention to the ambient temperature in the room where  

the   unit   is   operating.   Excessively   high   temperatures   cause   faster   ageing   of   the   internal  

components and shorten the fault-free time of unit operation. 

In cases where the unit gets dirty do not clean with solvents. For cleaning use warm water with  

small amount of detergent or in the case of more significant contamination ethyl or isopropyl  

alcohol. 

Using any other agents can cause permanent damage to the housing.

Product marked with this symbol should not be placed in municipal waste.

Please check local regulations for disposal and electronic products.

4.5. 

 

 BATTERY REPLACEMENT

 

 

Precautions when replacing the battery:

- Disconnect the wiring before changing the battery. Do not touch areas subject to  

high voltages as this could result to an electric shock.

- Make sure that your body is free from static electricity before changing the battery.

- Use only 3.6V 1/2AA Lithium Battery for this unit.

1) Use a flat screwdriver or any appropriate tool to lift the groove in order to unfasten rear case  

from front case.

2) Pull out the rear case from the main body.

8

Summary of Contents for SLE-42

Page 1: ...v 1 00 Type of input contact OC or voltage Self powered 3 6V 1 2AA Lithium Battery Read the user s manual carefully before starting to use the unit or software Please keep this manual for future refe...

Page 2: ...te installation not maintaining the proper technical condition and using the unit against its destination Installation should be conducted by qualified personnel During installation all available safe...

Page 3: ...side the control box does not exceed the recommended values In such cases forced cooling of the unit must be considered e g by using a ventilator The unit is designed for operation in an industrial en...

Page 4: ...protection IP 54 Wiring M3 terminal screw Housing type Housing dimensions Panel cut size Weight panel 48 x 24 x 39 7 mm 45 x 22 2 mm 1 mm approx 50 g battery included Operating temperature Storage tem...

Page 5: ...he unit from the protective packaging check for transportation damage Any transportation damage must be immediately reported to the carrier Also write down the unit serial number on the housing and re...

Page 6: ...User manual for electronic counters SLE 42 and STH 42 Figure 4 1 Panel cut out dimensions Figure 4 2 Installing of clip and gasket Figure 4 3 Dimensions of the case 6 Mounting Clip Panel Gasket...

Page 7: ...able shall be protected against destruction with an electrical installation fuse Wiring must meet appropriate standards and local regulations and laws In order to secure against accidental short circu...

Page 8: ...small amount of detergent or in the case of more significant contamination ethyl or isopropyl alcohol Using any other agents can cause permanent damage to the housing Product marked with this symbol...

Page 9: ...ain body Warning This unit uses Lithium battery Properly dispose the battery after use Do not short the positive and negative terminals recharge disassemble deform or dispose the battery to fire as th...

Page 10: ...User manual for electronic counters SLE 42 and STH 42 6 PRINCIPLE OF OPERATION a b Figure 6 1 The counting principle of the SLE 42 counters a dry contact OC NPN input b wide range voltage input 10...

Page 11: ...User manual for electronic counters SLE 42 and STH 42 11...

Page 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: