Operation
5
1. The shaft seal depends on water for
Performance
lubrication. Do not operate the pump unless
it is submerged in water; running it dry may
damage the seal.
2. If the pump overheats, an automatic-reset
thermal protector cuts off the power and stops
the motor before it can be damaged. The motor
will automatically restart when it cools. If the
protector trips repeatedly, unplug the pump,
remove it from the sump, and check it for
Model
FPSC2200A
FPSC2250A
FPSC3200A
FPSC3250A
FPSC4550A
GPH At Total Feet Of Lift
5 ft.
10 ft. 15 ft.
20 ft.
Capacity Gallons/Hour
4,020
3,540
3,000
1,800
4,020
3,540
3,000
1,800
4,380
3,840
3,300
2,340
4,380
3,840
3,300
2,340
4,700
4,100
3,500
2,820
No flow
at height
shown
below
26'
26'
28'
28'
32'
the cause of the difficulty. Low voltage, long
extension cords, clogged impeller, very low lift,
a plugged or frozen discharge pipe, etc., can
Electrical & Switch Specifications
all cause cycling and overheating.
3. This pump will not remove all the water in the
sump. If you are running the pump manually
and water stops coming out of the discharge,
the pump has probably run dry. Shut it off
immediately and check the water level.
Discharge
Pipe
•
Model
FPSC2200A
FPSC2250A
FPSC3200A
FPSC3250A
FPSC4550A
Basement
Floor
\
Sump
Pit
Motor
HP
1/3
1/3
1/2
1/2
3/4
=-
Motor
Individual
Branch
Full
Circuit
Load
Req.
Amps
{Amps)
6.9
15
6.9
15
7.0
15
7.0
15
7.7
15
Lift
1..,...._ ___ Check Valve
� (Install Vertically)
*Switch Setting
in inches
Water Level
For:
On
Off
15"
7"
6-1/2"
3"
15"
7"
6-1/2"
3"
6-1/2"
3"
Figure
7
-
Li� is the vertical distance the pump
actually li�s water. The higher the lift, the
lower
the
flow.
NOTICE The friction caused by water running
through the pipe will also, on longer pipe runs,
reduce the flow.
For parts or assistance, call Simer Customer Service at 800-468-7867