Simer Mini-Vac M40-01 Owner'S Manual Download Page 2

Installation / Operation

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867

INSTALLATION

1. Locate pump as close as possible to water

being pumped. Pump must be less than 10
feet (3m) above water reservoir and less than
25 feet (7.6m) to one side of reservoir.

2.

To help priming, pour one tablespoon of
cooking oil or mineral oil in inlet port before
each use.

Do this every time you start the

pump.

3. Mount pump solidly on a stable platform.

Risk of electrical shock.

Protect motor from rain or washdown; it is
enclosed but not waterproof.

4. Make sure washer in inlet fitting is clean and

in good condition. If this joint leaks air in,
pump will not operate.

5. Install a strainer or the Pud-L-Scoop

®

to pro-

tect the pump from large solids (Pud-L-Scoop

® 

is included with Models M40P-01 and 
M40P-03 only). When attached to a water
suction pump, the Pud-L-Scoop

®

will pump

water down to within 1/8” of the surface it is
sitting on. Uses include floors, roofs, pool
covers, and boat bilges. The threadless rubber
grommet can be connected to a 3/4” pipe or
garden hose. The washer end of the rubber
grommet inserts into the Pud-L-Scoop

®

and

the tapered end is for the hose connection.
Place the Pud-L-Scoop

®

at the lowest point in

the area to be pumped and it is ready for use.

6. Attach inlet and discharge hoses to pump. Use a

reinforced inlet hose 1/2" (12.7mm) in diameter
or larger. Be sure inlet hose is airtight and that
both hoses are free of kinks and restrictions.

7. Make sure hoses are as straight as possible.

Coils in the hoses can develop enough fric-
tion to prevent pump from operating.

8. When pumping from a well or stream, raise

inlet hose a few inches from the bottom to
prevent pump sucking sand, silt or pebbles
(foreign matter will disable impeller).

9. Plug motor cord into a 3-wire grounded 115

volt 60 Hz. A.C. outlet.  If necessary, use a 
3-wire, grounded extension cord to connect the
pump motor to the grounded outlet. Use a size
16 AWG cord up to 25 feet; do not use a cord
more than 25 feet long. Keep the pump, cord,
and outlet dry at all times.

Use this pump only on 115
volt circuit. Pump is equipped
with an approved 3-conductor
cord and 3-prong, grounding-

type plug. To reduce the risk of electric shock,
be certain that it is connected to a properly
grounded, grounding-type receptacle.

Where a 2-prong wall receptacle is encoun-
tered, it must be replaced with a properly
grounded 3-prong receptacle installed in accor-
dance with the National Electrical Code and
local codes and ordinances.

NOTICE: PUMP DEPENDS ON LIQUID BEING
PUMPED FOR LUBRICATION. DO NOT RUN
PUMP DRY!

10. Pump should prime within 30 seconds. If

not, unplug pump and do the following:

a. Disconnect inlet hose at pump. Pour

another tablespoon of mineral oil into
inlet port.

b. Check washers in inlet hose and make

sure inlet line is airtight.

c. Make sure inlet and discharge line are

free of kinks and restrictions.

d. Make sure pump is less than 10' (3m)

above and 25' (7.6m) to one side of
water source.

11. If pump does not prime within 30 seconds,

check step 10. If pump still fails to prime, do
the following:

a. If impeller is worn, replace it.
b. If pump head is internally worn, replace it.
c. Remember to add one tablespoon of oil

every time you start the pump.

NOTICE: 

When using the Pud-L-Scoop

®

, inspect

the washer in the garden hose fitting to be sure
it is in good condition. Be sure connections are
air tight. 
The Pud-L-Scoop

®

requires at least 1/2"

(12.7mm) minimum water depth to prime.

OPERATION

NOTICE: 

Do not run pump dry. Pump depends

on water being pumped for lubrication. If pump
does not prime in less than 30 seconds, recheck
installation and plumbing.
Pump will deliver 330 gallons (1249L) per hour
(5.5 gallons (20.8L) per minute) when discharge is
not restricted. As discharge is restricted  and dis-
charge pressure increases, capacity will decrease.
Do not operate pump continuously at a dis-
charge pressure of more than 12 psi (83 kPa) or
discharge lift of more than 28’ (8.5M). Motor
will exceed the normal safe operating tempera-
ture and can heat to 180°-190° F (82°-88° C)
when operated continuously at discharge lifts of
more than 28’ (8.5M).
Motor overload may trip if motor temperature
rises too high. Motor must have air circulation
around it for proper cooling. If motor overload
trips, allow motor to cool for 30 minutes before
attempting to start pump.

Risk of burns. 

During normal

operation, motor case may heat enough to burn

you. Do not touch the motor when it is hot.
Plug motor cord into 3-wire grounded 115 volt
A.C. outlet 60 Hz.

Risk of fire or explosion if used

to pump flammable liquids or if used in explo-
sive atmospheres. Pump water only with this
pump!

Pump is designed to pump 

at water temperatures between 32°-77° F 
(0°-25° C) only. 

Hazardous
voltage

Summary of Contents for Mini-Vac M40-01

Page 1: ...aintenance assistance Call 1 800 468 7867 English Pages 2 4 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468...

Page 2: ...grounded grounding type receptacle Where a 2 prong wall receptacle is encoun tered it must be replaced with a properly grounded 3 prong receptacle installed in accor dance with the National Electrica...

Page 3: ...49A includes the Pud L Scoop and a 6 garden hose with washer Slinger Only No RP0001616 Key No 10 Key Part No Description Qty 1 10 32x1 3 4 Phil Hd Screw 2 2 8x5 8 Phil Hd Screw 4 3 End Cover 1 4 O Rin...

Page 4: ...arranty This warranty shall not apply to acts of God nor shall it apply to products which in the sole judgement of SIMER have been subject to negligence abuse accident misapplication tampering alterat...

Page 5: ...r ceptacle 3 dents la masse mont conform ment au code lectrique nation al et aux arr t s locaux AVIS LA POMPE D PEND DU LIQUIDE POMP POUR SA LUBRIFICATION NE PAS FAIRE FONC TIONNER LA POMPE SEC 10 La...

Page 6: ...ntre parenth ses et 8 9 entre parenth ses C Les n cessaires de balais n FP003415S comprend une paire de balais de ressorts et de capuchons rempla ables Ref 11 Le Pud L Scoop n FP000349A comprend le Pu...

Page 7: ...cas de force majeure et ne s appliquera pas aux pro duits qui du seul avis de SIMER ont fait l objet de n gligence d utilisation abusive ou incor recte d accident de modification ou d alt ra tion ni a...

Page 8: ...3 clavijas bien conectado a tierra instalado seg n el C digo El ctrico Nacional y los c digos y ordenanzas locales AVISO LA BOMBA DEPENDE DEL L QUIDO BOMBEADO COMO LUBRICANTE NO HAGA FUNCIONAR LA BOM...

Page 9: ...uego de escobillas No FP003415S incluye un par de escobillas resortes y casquetes reemplazables Clave No 11 Pud L Scoop placa colectora No FP000349A incluye el Pud L Scoop y una manguera de jard n de...

Page 10: ...m plazar el producto cubierto por esta garant a Esta garant a no se aplicar a hechos de fuerza mayor ni se aplicar a los productos que a juicio exclusi vo de Simer hayan sido objeto de negligencia abu...

Page 11: ...11...

Page 12: ...12...

Reviews: