background image

Safety

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

Carefully read and follow all safety instructions in this manual
and on pump.

This is the safety alert symbol.

When you see this symbol

on your pump or in this manual, look for one of the fol-

lowing signal words and be alert to the potential for personal
injury.

warns about hazards that 

will 

cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that 

can 

cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.
Electrically powered sump pumps normally give many years of
trouble-free service when correctly installed, maintained, and
used. However, unusual circumstances (interruption of power to
the pump, dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in the pump,
etc.) may prevent your pump from functioning normally. To pre-
vent possible water damage due to flooding, consult your dealer
about installing a secondary sump pump, a DC backup sump
pump, and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common sump
pump problems and remedies. For more information, see your
dealer or call customer service at 1-800-468-7867.
1. Know the pump application, limitations, and potential 

hazards.

2. Disconnect the power before servicing.
3. Release all pressure within the system before servicing any

component.

4. Drain all the water from the system before servicing.

5. Secure the discharge line before starting the pump. An unse-

cured discharge line will whip, possibly causing personal
injury and/or property damage.

6. Check hoses for weak or worn condition before each use,

making certain that all connections are secure.

7. Periodically inspect the sump, pump and system compo-

nents. Keep free of debris and foreign objects. Perform rou-
tine maintenance as required. 

8. Provide a means of pressure relief for pumps whose dis-

charge line can be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when working with

pumps.

b. Keep work area clean, uncluttered and properly lighted –

replace all unused tools and equipment.

c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master

switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all electri-

cal and safety codes that apply.

11. This equipment is only for use on 115 volt and is equipped

with an approved 3-conductor cord and 3-prong, grounding-
type plug.

Hazardous voltage. Can shock, burn or

cause death. 

To reduce the risk of electric shock, pull the

plug before servicing. Pump is supplied with a grounding
conductor and grounding-type attachment plug. Be sure it
is connected only to a properly grounded grounding-type
receptacle.
Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle
installed in accordance with codes and ordinances that apply. 
This pump has not been investigated for use in swimming
pool areas. 

12.  A ground fault circuit interrupter is recommended for use

with any electrical appliance submerged in water. Installation
and all wiring should be performed by a qualified electrician.

13. Make certain the power source conforms to the requirements

of your equipment.

SIMER warrants to the original consumer purchaser (“Purchaser”) of its products that they are free
from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product
shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms
and conditions set forth below. Your original receipt of purchase is required to determine warran-
ty eligibility.

Exceptions to the Twelve (12) Month Warranty

Ninety (90) Day Warranty:

If within ninety (90) days from original consumer purchase any Drill Pump or MiniVac Pump shall
prove to be defective, it shall be replaced, subject to the terms set forth below.

Two (2) Year Warranty:

If within two (2) years from original consumer purchase, any 1/3 HP Submersible Sump Pump, or
Models 2330, 2300 or A5500,  shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below.

Three (3) Year Warranty:

If within three (3) years from original consumer purchase any 4” Submersible Well Pump, 1/2 HP
Submersible Sump Pump, or Booster Pump Model 3075SS shall prove to be defective, it shall be
repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below.

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any Pre-Charge water system tank shall
prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and
conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product covered by this
warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the
sole judgement of SIMER, have been subject to negligence, abuse, accident, misapplication, tam-
pering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other
than normal application, use or service, including but not limited to, operational failures caused
by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of
recommended maximums.
Requests for service under this warranty shall be made by returning the defective product to the
Retail outlet or to SIMER as soon as possible after the discovery of any alleged defect. SIMER will
subsequently take corrective action as promptly as reasonably possible. No requests for service
under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective
products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT
EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED
HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or lim-
itations on how long an implied warranty lasts, so the above limitations or exclusions may not
apply to you. This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.

Simer Limited Warranty

SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115

Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351

EMail: [email protected] • Web: http://www.simerpumps.com

Summary of Contents for 2975PC

Page 1: ...le 1 800 468 7867 Fran ais Pages 7 11 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 12 16...

Page 2: ...d by a qualified electrician 13 Make certain the power source conforms to the requirements of your equipment SIMER warrants to the original consumer purchaser Purchaser of its products that they are f...

Page 3: ...with salt water or brine will void warranty Pump water only with this pump PERFORMANCE INSTALLATION 1 Install the pump in a sump pit with a minimum diameter of 12 305mm Construct the sump pit of tile...

Page 4: ...y and restart the motor If the protector trips repeatedly unplug the pump and remove it check for cause of difficulty Low voltage extension cords clogged impeller very low head or lift etc could cause...

Page 5: ...ze Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company or hydro authority Defective motor Replace pump Defective float s...

Page 6: ...7 1 3 4 5 2 6 7 4073 0901 Key Part No Description Qty 2975PC 1 Power Cord 1 227 264 B TSU 2 Float Switch 1 PS117 144P 3 Motor Assembly 1 4 Impeller 1 416 018 5 Volute 1 6 Suction Housing 1 772 010 7 S...

Page 7: ...ne comporte que 2 trous elle devra tre rem plac e par une prise de courant 3 trous dont un de mise la terre De plus elle devra tre pos e conform ment aux codes et aux r gle ments en vigueur Cette pom...

Page 8: ...pour pomper de l eau sal e ou de la saumure Pomper de l eau sal e ou de la saumure annulera la garantie Ne pomper que de l eau avec cette pompe D BITS INSTALLATION 1 Installer la pompe dans un puisard...

Page 9: ...t tr s basse etc risquent de causer cet incident Risque de d marrages brusques pouvant causer des secousses lectriques et des blessures corporelles Le moteur de la pompe est prot g par un dispositif d...

Page 10: ...x Interrupteur flotteur d fectueux Remplacer l interrupteur flotteur La pompe ne s arr te pas Interrupteur flotteur d fectueux Remplacer l interrupteur flotteur Refoulement obstru D poser la pompe et...

Page 11: ...0 546 7867 1 3 4 5 2 6 7 4073 0901 R f D signation Qt 2975PC 1 Cordon lectrique 1 227 264 B TSU 2 Interrupteur flotteur 1 PS117 144P 3 Moteur 1 4 Impulseur 1 416 018 5 Volute 1 6 Carter d aspiration 1...

Page 12: ...re spondan No se ha investigado la operaci n de esta bomba para su uso en reas de piscinas de nataci n 12 Se recomienda usar un disyuntor de escape a tierra con todo aparato el ctrico sumergido en agu...

Page 13: ...a garant a Bombee solamente agua con esta bomba DESEMPE O INSTALACI N 1 Coloque la bomba en un foso de sumidero con un di metro m ni mo de 12 305 mm Construya el foso de sumidero de baldosas hormig n...

Page 14: ...se dispara repetidamente desenchufe la bomba y s quela verifique cu l es la causa del problema Baja ten si n cordones de alargue impulsor obstruido muy poca altura o alza etc puede provocar los ciclos...

Page 15: ...lace el interruptor de flotador La bomba arranca y se Interruptor de flotador defectuoso Reemplace el interruptor de flotador detiene con demasiada Descarga restringida Saque la bomba y limpie la bomb...

Page 16: ...073 0901 Clave Descripci n de No la pieza Cant 2975PC 1 Cord n el ctrico 1 227 264 B TSU 2 Interruptor de flotador 1 PS117 144P 3 Unidad del motor 1 4 Impulsor 1 416 018 5 Voluta 1 6 Caja de aspiraci...

Reviews: