USER INSTRUCTIONS

VERY IMPORTANT!

PLEASE MAKE SURE YOUR LOG BOOK ENCLOSED IS FILLED IN CORRECTLY.

ALL CORGI REGISTERED INSTALLERS CARRY A CORGI ID CARD.

BOTH SHOULD BE RECORDED IN YOUR CENTRAL HEATING LOG BOOK.

YOU CAN CHECK YOUR INSTALLER IS CORGI REGISTERED

BY CALLING ON 01256 372300

GAS  SAFETY  [INSTALLATION  AND  USE]  REGULATIONS  [as
amended].  It  is  the  law  that  a  registered  person,  in  accor-
dance with the above regulations, installs all gas appliances.
Failure  to  install  appliances  correctly  could  lead  to  prosecu-
tion.  It  is  in  your  own  interest,  and  that  of  safety,  to  ensure
that the law is complied with.

It is essential that the appliance be correctly earthed.
An  electricity  supply  of  230  V~  50  Hz  fused  at  3  A  is
required.

Read these instructions carefully before attempting to oper-
ate the appliance.

1.1

INTRODUCTION

The Sime “

Superior Ci

” are a range of wall mounted cast iron

boilers. They utilise a fully automatic ignition system together
with electronic temperature control. The combustion system
is  fan  assisted  and  uses  a  concentric  flue  and  air  duct  that

can  exit  the  boiler  to  either  side  or  to  the  rear,  ending  in  a
small balanced flue terminal on the outside wall.
The appliance is suitable for use with natural gas.

1.2

APPLIANCE OPERATION

The installation engineer will have set the range rated appli-
ance  to  the  correct  heating  requirement  for  the  property.
There should be no need to adjust the boiler control once it
has  been  set  unless  the  temperature  set  point  needs  to  be
increased or decreased. The thermostat knob will adjust the
set point temperature of the electronic controls in the appli-
ance. Turning clockwise increases the set point.
A demand for heat from the external controls will:
– check the air pressure switch,
– start the fan,
– confirm correct air flow through the appliance,
– start the spark generator,
– open the gas valve,
– ignite and prove the flame,
– monitor  the  appliance  flow  temperature,  switching  the

appliance on and off as necessary.

– should the appliance fail to light, the lockout button will illu-

minate.

1.3

OPERATING INSTRUCTIONS

1.3.1

To light the appliance

– Turn on the electrical supply and set all external controls

to on.

– Turn the boiler control to maximum and check the pump is

operating correctly and water is circulating.

– After a short period the ignition lockout indicator will be illu-

minated, after a 10 second wait depress the lockout button
to reset the ignition sequence. Turn off the boiler control.

OPERATING INSTRUCTIONS FOR THE USER

IGNITION AND

TEMPERATURE CONTROL

LOCK-OUT BUTTON

OVERHEAT WARNING LAMP

APPLIANCE CONTROLS