100
sealant if necessary.
4.4
DISMANTLING THE CASING (fig. 21)
The casing may be removed completely to
facilitate boiler maintenance, as shown in
fig. 21. Turn the panel control forward for
access to the internal components of the
boiler.
4.5
MAINTENANCE
To guarantee functioning and efficiency of
the appliance, in respect of the legal provi-
sions in force, it must be regularly checked;
the frequency of the checks depends on
the type of appliance and the installation
and usage conditions.
In any case, it should be inspected at least
once a year by a qualified technician.
Carry out the cleaning of the generator in
the following way:
– Turn the main switch off to stop electric
power reaching the boiler and close the
gas feed cock.
– Remove the outer casing and the gas
burner manifold unit. To clean the burner,
blow in a jet of air, so as to remove any
dust particles that may have accumula-
Fig. 21
ATTENTION
Before removing or refitting the
front panel of the boiler, open the
small upper plastic door.
Codice/Code 8106610
Modello/Model MURELLE EV 25/55 BF
Matricola/Serial n. 9999999999
PAR 1 = 2 (G20) / 6 (G30-G31)
PAR 2 = 3