Malfunction codes and possible solutions
LIST OF MALFUNCTION/FAULT ALARMS
Type
No.
Fault
Solution
E
01
Fault in the flame
detection circuit
- Check the integrity of the
electrode and check that it
is not grounded
- Check gas availability and
pressure
- Check the integrity of the
gas valve and the card
E
02
Safety thermostat
intervention
- Check the sensor or
thermostat connections
- Deaerate the system
- Check the bleed valve
- Replace the sensor or the
thermostat
- Check that the pump
impeller is not blocked
E
04
Low water pressure in
system
- Restore pressure
- Check for any leaks in the
system
E
05
Air pressure switch
intervention
- Check the air pressure
switch and fan
- Check any blockage of the
silicone pipe between the
fan and the air pressure
switch and check the
correct positioning of the
pipe on pressure switch
point P2
- Check the correct usage
of the segmented air
diaphragm
- Check any blockage of
the flue gas outlet and air
inlet ducts
E
06
Domestic hot water
sensor fault
- Check connections
- Check the sensor is
working
E
07
Delivery sensor fault
- Check connections
- Check the sensor is
working
E
09
No water circulating in
the system
- Check the rotation of the
pump rotor
- Check the electrical
connections
- Replace the pump
E
11
Parasite flame fault
- Check that the electrode
is intact or that it is not
earthed
E
12
Gas valve modulator
disconnected
- Check the electrical
connection
E
28
Maximum number of
consecutive resets
reached
- Wait 1 hour and try
unblocking the board
again
- Contact the Technical
Assistance Centre
E
37
Fault due to low
network voltage
- Check the voltage
- Contact your network
provider
E
40
Incorrect network
frequency detected
- Contact your network
provider
E
41
Flame loss more than
6 consecutive times
- Check the ignition/
detection electrode
- Check the gas supply
(open valve)
- Check mains gas pressure
E
42
Button fault
- Check that buttons are
working
E
43
Open Therm
communication fault
- Check the OT electric
connection
Type
No.
Fault
Solution
E
44
Gas valve timeout fault
without flame
- Check gas valve and board
E
72
The ΔT requested at
start-up has not been
reached
- Check the correct position
of the delivery sensor
E
80
Fault on the gas valve
control logic line/valve
cable damaged
- Check the gas valve,
board, electrode and valve
cable
E
88
Internal error (board
component protection)
- Check the board is
working
- Replace board
888
Over temperature
- Check the delivery probe
- Check flue gas outlet
- Check system pump
E
98
SW error, board
start-up
- Contact the Technical
Assistance Centre
E
99
Generic error
- Contact the Technical
Assistance Centre
-
-
Frequent relief valve
intervention
- Check circuit pressure
- Check expansion vessel
-
-
Limited production of
domestic hot water
- Check the diverter valve
- Check that plate heat
exchanger is clean
- Check domestic hot water
circuit valve
Summary of Contents for GO 18 BF G20
Page 10: ...10 ES...
Page 18: ...18 ES...
Page 41: ...41 ES...
Page 50: ...50 EN...
Page 58: ...58 EN...
Page 81: ...81 EN...
Page 83: ...83 RU m Sime 1 1 2 OFF Sime X m Fonderie SIME S p A...
Page 84: ...84 RU d 8 8 OFF d EN 15502 60 C 5 C...
Page 90: ...90 RU...
Page 91: ...91 RU 5 92 5 1 92 5 2 92 5 3 92 5 4 93 5 5 94 5 6 95 5 7 95 5 8 95 5 9 96 5 10 96 5 11 97...
Page 98: ...98 RU...
Page 101: ...101 RU 50 mm 300 mm 900 mm 25 6 5 GO BF m 6 6 m Y R 6 7 pH 6 8 25 f 6 8 GO BF 1 2 3 1 2 3 26...
Page 109: ...109 RU 6 13 2 3 4 7 7 3 4 3 7 45...
Page 111: ...111 RU 7 3 m 1 2 1 2 49 t 6 OFF RESET 50 5 tS0 1 1 1 1 1 1 1 5 5...
Page 116: ...116 RU 7 8 Auto MAnu 1 5 m 6 7 65 tS 1 7 5 t D 5 Auto OFF RESET 66 P01 0 150 6 D 67...
Page 118: ...118 RU 8 8 1 m a OFF OFF 70 8 2 8 2 1 d 8 3 8 3 1 1 2 1 2 71 3 4 4 5 6 3 72 5 6 5...
Page 119: ...119 RU 8 3 2 8 3 3 3 5mm 0 5 0 5 73 m 8 3 4 4 4 4 74 8 4 8 4 1 8 4 2 1 8 5...
Page 121: ...121 RU...
Page 122: ...122...
Page 123: ...123...