1 BOILER IGNITION 

(fig. 1)

Open the gas cock and position the index of
the selector knob in the following positions: 

• With the rotary switch in the summer

position (

), the boiler will start-up

upon demand for domestic hot water,
and will start to modulate in automatical-
ly to reach the selected temperature. 
The gas feeding pressure will then auto-
matically vary to ensure  that the requi-
red temperature is kept constant.

• With the rotary switch  in the winter

position (

), once the boiler has rea-

ched the value set on the heating poten-
tiometer, it will start to modulate in auto-
matically in order to supply the required
power output to the system.
The operation of the boiler will be stop-
ped through the intervention of the room

thermostat or the programable thermo-
stat.

ATTENTION: no noise is produced when
you position the index of the knob on the
desired setting.

2 TEMPERATURES 

ADJUSTMENT

(fig. 2)

1. The D.H.W. temperature can be adju-

sted by turning the knob of the D.H.W.
potentiometer

which has a range of

between 30 to 60°C (86-140° F) .

2. The C.H. temperature can be adjusted by

turning the knob of the C.H. potentiome-
ter

which has a range of between 30

to 80°C (86-176° F)

3. To ensure optimal boiler efficiency at all

times, we recommend not to drop below

a minimum working temperature of 50°C
(122° F).

TURNING THE BOILER OFF

(fig. 1)

When the selector is in OFF position, the
boiler is in standby, the green LED flashes
at intervals of five seconds and all featu-
res are disabled, except the pump anti-
blocking feature. Move the bipolar switch
to “OFF” to disconnect the unit from the
power supply. 

If the boiler is not going to be used  for a
lengthy period it is advised to turn off the
electricity supply, close the gas cock, and if
low temperatures are foreseen, empty the
boiler and the hydraulic system to avoid
breakage in the tubes due to the freezing of
the water.

2

4

5

3

Apre

2

4

5

3

Figure 1

4

5

2

3

Figure 2

OPEN

USER INSTRUCTIONS

Summary of Contents for Format.zip

Page 1: ...User Instruction and Care Guide Format zip of Gas Fired Wall Hung Hot Water Boilers CND USA...

Page 2: ......

Page 3: ...ety information above on this label If you don t smell gas go to next step 8 Set the heating potentiomenter to the desired setting 9 Set thermostat to desired setting if applicable 10 Connect electric...

Page 4: ...g 2 TEMPERATURES ADJUSTMENT fig 2 1 The D H W temperature can be adju sted by turning the knob of the D H W potentiometer which has a range of between 30 to 60 C 86 140 F 2 The C H temperature can be...

Page 5: ...FAULTS FINDING A Ignition failure safety stat intercep tion fig 3 If the burner fails to start the red led that signals blockage will light up To attempt starting it again the selector knob must be tu...

Page 6: ...ctio ning If the indicator light comes on again turn off the boiler and request assistance from an Authorised Technical Service Centre If the boiler and the green voltage LED switch off it is possible...

Page 7: ...curit situ es au dessus de cette tiquette Si vous ne sentez pas de gaz passez l tape suivante 8 Placez les potentiom tres de chauffage sur le r glage souhait 9 Placez le thermostat sur le r glage sou...

Page 8: ...de l eau chaude sanitai re peut tre r gl e avec la molette du potentiom tre de l eau chaude sani taire entre 30 et 60 C 86 140 F 2 La temp rature de l eau de chauffage peut tre r gl e avec la molette...

Page 9: ...sente l int rieur de la sor tie d air devra tre enlev e avec une brosse poils doux 6 RECHERCHE DES PANNES A Panne d allumage intervention du thermostat de s curit fig 3 Si le br leur ne d marre pas le...

Page 10: ...le t moin s claire nouveau tei gnez la chaudi re et faites intervenir le service apr s vente Si la chaudi re et le t moin verte de tension s teignent vous pouvez r ar mer l appareil en le d branchant...

Page 11: ......

Page 12: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it Cod 6272247 07 09 Documentation Dpt...

Reviews: