5
2.1
INSTALLATION
Models
“34E BF”
with a hermetically sealed combustion cham-
ber and air supply circuit, may be installed outdoor.
Models
“34I BF”
with a hermetically sealed combustion cham-
ber and air supply circuit, may be installed in any room in the
home.
2.2
CONNECTING UP SYSTEM
Wash all system pipes well before hooking them up with the
boiler to eliminate any residues which could compromise its
functioning.
The discharge pipe must be connected and extend the pipe
to ensure that any discharge is safety routed any.
THE BOILERS MUST BE INSTALLED STRICTLY IN ACCOR-
DANCE WITH THESE INSTRUCTIONS AND MEET THE
NATIONAL GAS INSTALLATION STANDARD AS 5601.
AND ANY LOCAL WATER AND ELECTRICAL STATE AND
LOCAL GOVERNMENT REGULATIONS WHICH MAY BE
APPLICABLE.
For installations where the heater is connected to larger
systems, the additional volume will need to be taken into
account.
A temperature pressure relief valve may be needed.
An adhesive data plate is sticked inside the front panel; it con-
tains all the technical data identifying the boiler and the type
of gas for which the boiler is arranged.
2.3
CHARACTERISTICS OF FEEDWATER
To prevent lime scale and damage to the tap water exchan-
ger, the water supplied should have a hardness of no more
than 20°F. In all cases the water used should be tested and
adequate treatment devices should be installed.
2.4
FLUE TERMINAL POSITION MODEL “34I BF”
The outlet terminals for forced draught systems may be
located on the outer walls of the building. Fig 4 shows
approximate, non-binding minimum distances to be met for a
building of the type shown in fig. 4.
2
GENERAL REQUIREMENTS FOR INSTALLATION
Fig. 4