Sime Ecomfort Plus User Instructions Download Page 4

4

OPERATING INSTRUCTIONS FOR THE USER

Fig. 1

KEY

A

Temperature/pressure gauge

B

Receiver time programmer (code 8092221/23)

C

Selector switch summer/winter

D

D.H.W. thermostat (it does not include SYSTEM 25 HE)

E

C.H. thermostat

THE  GAS  SAFETY  (INSTALLATION  AND  USE)  REGULATIONS
1996.  It  is  the  law  that  all  gas  appliances  are  installed  by  a
registered person, in accordance with the above regulations.
Failure  to  install  appliances  correctly  could  lead  to  prosecu-
tion.  It  is  in  your  own  interest,  and  that  of  safety,  to  ensure
that the law is complied with.

It  is  essential  that  the  appliance  is  correctly  earthed.  An
electricity supply of 240 V - 50 Hz fused at 3 A is required.

Read these instructions carefully before attempting to oper-
ate the appliance.

1.1

INTRODUCTION

The Sime 

“ECOMFORT PLUS” 

is a fully automatic, wall mount-

ed, room sealed, fan assisted combination boiler. When oper-
ating  in  winter  mode,  the  appliance  provides  central  heating
as  required  and  produces  instantaneous  hot  water  upon
demand. 
When operating in summer mode, the central heating is not
operational  however  the  appliance  continues  to  supply  hot
water  whenever  it  is  required.  The  heat  output  is  automati-
cally controlled by the fully modulating gas valve (within its pre-
set  limits),  and  there  are  user  adjustable  potentiometers  to
control the temperature of both central heating and domes-
tic hot water. A temperature/pressure gauge is fitted and an
overheat  thermostat  is  incorporated  to  protect  against  fault
conditions.

1.2

APPLIANCE OPERATION

A  demand  of  hot  water  will  be  sensed  by  the  appliance
detecting water flow (providing that the flow rate is above 2
l/m - 0.5 gal/min).
The  fan  will  start  and  the  burner  will  light  at  full  output.  If

the  draw  off  rate  is  near  the  maximum  design  flow  rate
the appliance will run continuously at full output until a tap
is  either  turned  off  or  the  flow  rate  is  reduced  in  which
case the heat output will reduce accordingly to maintain a
steady temperature.
Hot water is made available almost immediately at the appli-
ance outlet, but the final temperature and time taken for the
hot  water  to  reach  a  tap  depends  upon  the  potentiometer
setting, the rate at which water is drawn off, and the length
of the pipe between the boiler and the tap. 
When  the  tap  is  turned  off,  the  appliance  will  revert  to  C.H.
mode (if set on winter position) otherwise the burner will be
extinguished pending the next demand for hot water.

1.3

OPERATING INSTRUCTIONS

1.3.1

To light the appliance (see fig. 1)

– Check that the electricity supply is off and that the D.H.W.

isolation valve is in the open position (lever vertical). Check
that the gas supply is on.

– Turn the selector switch summer/winter (C) to SUMMER

(water only) position “

”.

– Switch  on  the  electricity  supply  and  full  open  any  D.H.W.

tap. The burner will light. 
If  the  burner  fails  to  light,  turn  the  selector  switch  sum-
mer/winter to  “

“  position  and  release  it  immediately;

then  turn  it  to  the  SUMMER  position:  the  burner  should
now light. Turn off the tap.

– Check  that  the  room  thermostat  and  time  clock  are  call-

ing  for  heat.  Turn  the  heating  potentiometer  (E)  to  maxi-
mum (fully clockwise).

– Turn  the  selector  switch  summer/winter to  the  WINTER

position “

" and the burner will light to serve the heating load.

Set  the  required  temperature  for  the  C.H.  and  D.H.W.  by

A

E

C

F

B

D

DHW

ISOLATION VALVE

Summary of Contents for Ecomfort Plus

Page 1: ...ECOMFORT PLUS User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER...

Page 2: ......

Page 3: ...CLOCK Code 8092214 8 ANALOGIC RF TIME PROGRAMMER Code 8092221 9 DIGITAL RF TIME PROGRAMMER Code 8092223 10 These appliances comply with the S E D B U K scheme band A CONTENTS VERY IMPORTANT PLEASE MA...

Page 4: ...he appliance detecting water flow providing that the flow rate is above 2 l m 0 5 gal min The fan will start and the burner will light at full output If the draw off rate is near the maximum design fl...

Page 5: ...s checked and serviced as necessary at regular intervals The frequency of servicing will depend upon the particular installation conditions and usage but in general once a year should be adequate It i...

Page 6: ...red black the wire which is coloured brown must be connected to the ter minal marked with the letter L or coloured red 1 6 4 Ventilation If the appliance is installed in a cabinet the latter MUST NOT...

Page 7: ...tappets that remain at the centre of the dial will be the OFF periods N B The smallest switching time ON or OFF is 15 minutes To select Timed mode move the selector switch in the middle of the clock f...

Page 8: ...e the operation in memory and go on to the next program Repeat the same procedure to set the remaining programs When finished programming set the selector to RUN position Deleting one or more programs...

Page 9: ...9 ANALOGIC RF TIME PROGRAMMER Code 8092221 The boiler will operate in emergency mode heating on for 4 min off for 9min if the batteries are removed or discharged...

Page 10: ...10 DIGITAL RF TIME PROGRAMMER Code 8092223 The boiler will operate in emergency mode heating on for 4 min off for 9min if the batteries are removed or discharged...

Page 11: ...and illustrations provided in this manual have been carefully prepared but we reserve the right to make changes and improvements in our products that may affect the accuracy of the information contain...

Page 12: ...Documentation Dpt Sime Ltd 1a Blue Ridge Park Thunderhead Ridge Glasshoughton Castleford WF10 4UA Customer Service 0870 9911114 Sales 0870 9911116 Technical Support 0870 9911117 Main Fax 0870 9911115...

Reviews: