13 REMOVING COMPONENTS
m
CAUTION
The maintenance interventions described must ONLY
be carried out the professionally qualified personnel.
a
WARNING
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance are
touched.
13.1 Remove panels
13.1.1 Front panel
To access the internal parts of the boiler:
– disassemble the smoke outlet duct of the
Brava Slim 30 BFRe
– remove the screws (1), pull the front panel (2) forwards and
release it from the top by lifting it
1
2
Fig. 62
13.1.2 Side panels
– Unscrew the screws (3)
– pull the side panel (4) outwards to release it from the top
3
4
Fig. 63
– proceed in the same way for the other panel.
13.1.3 Sealed chamber panel
– remove the four screws (3) and remove the front panel (4)
from the sealed chamber
3
4
Fig. 64