4

If it is too hot or too cold in your apartment, you can easily adjust the fixed
temperature with the temperature knob.

Before adjusting it again, however, allow the temperature to stabilise first.

Note: 

With  the  temperature  knob  you  can  only  adjust  the  fixed  temperature,  whilst  the

reduced temperature remains the same.

Adjusting the temperature

If you turn the knob towards the + sign, the fixed temperature is
increased by about 1 °C for every notch. 

If  you  turn  the  knob  towards  the  -  sign,  the  fixed  temperature  is
decreased by about 1 °C for every notch.

Before adjusting the temperature of the Logica controller, the thermostatic valves, which
may be present, have to be regulated to the desired temperature.

For every operation of the Info key the follow-
ing  list  of  items,  one  after  the  other,  are  dis-
played.  The  thermosensor  continues  to  func-
tion independently of the display.

Day, hour, room temperature

External temperature*

D.H.W. temperature*

* This data appear only if the relative sensor

is  connected  or  if  they  are  transmitted  by
the regulator of the boiler.

Info key

(reference key grey colour)

The  operating  mode  desired  is  selected  by
pressing the relative key with the correspond-
ing  symbol.  The  choice  is  displayed  with  the
symbol  

Automatic functioning: 

the heating functions automatically according to the heat-

ing programme entered. The programme may be excluded for brief periods with the
on-line key.

Manual functioning: 

the heating functions manually according to the choice made

with the on-line key.

Availability: 

the heating is deactivated.

Selection of the operating mode 

(reference keys grey colour)

ACTIVATING

During operation the lid of the Logica controller must be closed.

Summary of Contents for benchmark Planet Super 4 W. M.

Page 1: ...Planet Super 4 W M User Instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER ...

Page 2: ......

Page 3: ...knob The set temperature is displayed on the scale of the red leds from 40 80 C Regulation of the C H temperature is carried out by acting on the heating knob The set temperature is shown on the scale of the red leds from 40 80 C To guarantee an always optimal output from the generator it is advised not to go below a minimum operating tempera ture of 50 C TURNING OFF BOILER fig 1 To turn the boile...

Page 4: ...ing open the filling cock until the green led 1 bar lights up Once filled close the filling tap If all the leds are off call the authorised technical staff Safety stat interception fig 5 If the safety stat intercedes the red led 35 C intermittently lights up To start the boiler again turn the selector knob in the position and then release immedi ately returning it to the winter or summer function ...

Page 5: ...lacing the selector on the or posi tion obviously without consequent con trol of the room temperature The functioning instructions are inside the lid fig 8 Every setting or modifica tion is displayed and confirmed on the display fig 9 LOGICA REMOTE CONTROL 1 6 7 8 4 5 3 2 KEY 1 Display 2 Info key 3 Operating mode key automatic functioning 4 Operating mode key manual functioning 5 Operating mode ke...

Page 6: ...the follow ing list of items one after the other are dis played The thermosensor continues to func tion independently of the display Day hour room temperature External temperature D H W temperature This data appear only if the relative sensor is connected or if they are transmitted by the regulator of the boiler Info key reference key grey colour The operating mode desired is selected by pressing ...

Page 7: ...r at reduced level To have access to the reduced D H W temperature parameter press the and keys at the same time for at least 5 seconds and then go along the entered lines with the key until parameter 61 is reached Regulate the value with and Before proceeding with the adjustment in the temperature on the Logica controller the ther mostatic valves which may be present have to be regulated to the d...

Page 8: ...mperature of the D H W tank is regulated to the value set with user parameter n 3 In the reduced areas of heating the temperature of the D H W tank is regulated to the value set with parameter n 61 of the service level 2 service disconnected 3 second daily programme 8 Every day of the week the temperature of the hot water is set according to programme 8 In this case there is a single programming f...

Page 9: ...period 1 10 18 Vacation function To enter the number of days of absence In the display the vacation symbol will be shown on the left the day of activa tion 1 Monday 7 Sunday and on the right the number of vacation days 18 During the vacation the regulator will be on the availability mode When the set days have elapsed the regulator will go on to the automatic function NOTE The vacation period may ...

Page 10: ...ure Restore functioning by opening the filling cock of the boiler fig 4 System overpressure Call the authorised technical staff for assistance Safety stat interception Call the authorised technical staff for assistance Air pressure switch interception Call the authorised technical staff for assistance Failure of the modulating coil Call the authorised technical staff for assistance Communication f...