37
IT
ES
ENG
RUS
SL
Viewing of screen
Description
U/M
Field
Approved
calibration
Round 25 Round 50
2.7.1
Approved calibration
Sec
0,0 ÷ 60,0
2,0
rpm
0 ÷ 300
110
Sec
0,0 ÷ 60,0
2,8
rpm
0 ÷ 300
120
Sec
0,0 ÷ 60,0
3,7
rpm
0 ÷ 300
130
Sec
0,0 ÷ 60,0
4,6
rpm
0 ÷ 300
140
Sec
0,0 ÷ 60,0
5,5
rpm
0 ÷ 300
150
2,5
160
4,3
185
6,2
210
7,3
225
8,5
240
Viewing of screen
Description
U/M
Field
Factory default setting
PAGE - TEST
Resistance Start-up / Shut-
down
Ignition resistance
ON/OFF
OFF
Air Start-up / Shut-down
Activates 24V electrovalve power supply for the compressed air kit
ON/OFF
OFF
Alarm Start-up / Shut-down Activates the 230V output
ON/OFF
OFF
Cochlea Shut-down
Internal cochlea
ON/OFF
OFF
Tank shut-down
External cochlea
ON/OFF
OFF
Internal Fan
Burner fan
rpm
0 ÷ 300
External Fan
Cochlea fan
rpm
0 ÷ 300
NOTA
This checks that the main components of the burner are working correctly
REMOTE CONTROL
Module
Must be activated to connect the GSM module to connector 6 on the
burner
YES / NO
NO
2.7.2
A
larm messages
In the event of a fault or malfunction, the following signs appear on the screen:
Description
Failed ignition
Blackout alarm
Faulty water probe alarm
TS overheating
2.7.3
Problems - Possible causes -
S
olutions
In the table below are reported the most common problems with their possible solutions.
Problem
Possible cause
Solution
Failed ignition
Empty pellet container
Fill the container
Disconnected or broken external cochlea cable
Ignition resistance broken
Check the resistance and/or substitute it
Combuston grill is blocked
Pull out the grill and clean it
Internal cochlea blocked
Check the internal cochlea and remove any
blockages
Power supply absent
Electrical supply to burner not present
Check the mains supply
Check that the electrical cables are connected
correctly
Check that the general switches and the switches
on the burner are in the correct position
Water probe
The probe is incorrectly positioned or connected
Check its position and connections
Probe faulty
Replace the probe
Pellet container empty
Fill the container
Disconnected or broken cochlea cable
Re-establish the connection
Cochlea motor not working
Check the motor
Power 1
Filling Time from external cochlea to Power 1.
Fan
Fan speed at Power 1.
Power 2
Filling Time from external cochlea to Power 2.
Fan
Fan speed at Power 2.
Power 3
Filling Time from external cochlea to Power 3.
Fan
Fan speed at Power 3.
Power 4
Filling Time from external cochlea to Power 4.
Fan
Fan speed at Power 4.
Power 5
Filling Time from external cochlea to Power 5.
Fan
Fan speed at Power 5.
NOTA
Summary of Contents for B-Essential Round 50
Page 1: ...B Home Round 25 B Essential Round 50 Fonderie SIME SpA Cod 6113743 07 2019 IT ES ENG RUS SL...
Page 2: ......
Page 42: ...42 1 9 8 20 20 1 10 6 DIN PLUS 25 3 650 5 8 1...
Page 44: ...44 1 12 1 2 3 4 5 10 90 C...
Page 46: ...46 2 6 EN IT ES FR DE o o o o 24 03 2015 o o o o 12 24 F C 12 24 F C...
Page 47: ...47 IT ES ENG RUS SL o o o o o o o o o 1 2 3 4 A B C D 1 2 3 4 5 2 7 00 00 2 H2O 10 90 C 1 7...
Page 64: ......
Page 89: ...89 IT ENG RUS ES SL 2 2 1 A 1 2 3 1 B 2 4 5 2 C 6 7...
Page 90: ...90 D 8 E F 1 5 9 A B C 10...
Page 108: ...108 NOTE...
Page 119: ......