![Sime 8501546 Installation & Servicing Instructions Manual Download Page 18](http://html1.mh-extra.com/html/sime/8501546/8501546_installation-and-servicing-instructions-manual_1275163018.webp)
18
EN
TABLE OF CONTENTS
RANGE
NON-RECLINABLE FIXED FRAMES FOR ROOF
PITCH
CODE
Pitch kit - 1 SimePlano 272 collector
8501546
Pitch kit - 2 SimePlano 272 collectors
8501547
Pitch kit - 3 SimePlano 272 collectors
8501548
Pitch kit - 4 SimePlano 272 collectors
8501549
Pitch kit - 5 SimePlano 272 collectors
8501550
Pitch kit - 6 SimePlano 272 collectors
8501551
KIT WITH PAIR OF FASTENINGS
CODE
Kit with fixing brackets for collectors
RESTING on roof for installation on pitch
5801700
Kit with fixing brackets for collectors
SUSPENDED for shingles for installation on pitch
5801500
Kit with fixing brackets for collectors
SUSPENDED for tiles for installation on pitch
5801900
Kit with fixing brackets for collectors
TILE DRILLING for installation on pitch
5801600
COMPLIANCE
In designing and inspecting the machine’s structural elements,
the regulations and standards currently in force were observed,
namely:
– (Italian) Ministerial Decree 09/01/96, Part Two: technical
rules for the calculation, execution and testing of steel
structures;
– UNI - EN 10025: hot rolled products of structural steels.
Technical delivery conditions for non-alloy structural steels;
– NTC 2008 - Technical rules for constructions - Min. Decree of
14 January 2008;
– UNI ENV 1991 - 1 Calculation bases and actions on structures.
1312
Refer to the technical data plate for the serial number and year
of manufacture.
SYMBOLS
a
WARNING
Refers to actions that, if not carried out correctly, may
lead to generic injuries or may damage the appliance
or cause it to malfunction; these actions, therefore,
require special care and adequate training.
f
ELECTRICAL HAZARD
Refers to actions that, if not carried out correctly, may
lead to injuries deriving from electrical sources; these
actions, therefore, require special care and adequate
training.
d
IT IS FORBIDDEN
Refers to actions that MUST NOT BE carried out.
m
WARNING
Refers to particularly important and useful
information.
1 FASTENING
21
1.1 Fastening on pitch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.1.1 Fastening resting on roof code 5801700. . . 21
1.1.2 Suspended fastening code 5801500 . . . . . . 22
1.1.3 Fastening for roof tiles code 5801900 . . . . . 22
1.1.4 FASTENING FOR DRILLED SHINGLES code
5801600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.1.5 Parallel to roof pitch with kit resting on roof
code 5801700. . . . . . . . . . . . . . . . . . . . . . . . . 24
1.1.6 Parallel to roof pitch with suspended kit code
5801500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.1.7 Parallel to roof pitch with suspended kit code
5801900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.1.8 Parallel to roof pitch with drilling kit code
5801600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2 APPLICATION OF FASTENINGS
28
2.1 Fixed frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.1.1 Shingle drilling code 5801600 . . . . . . . . . . . 28
2.1.2 Resting on roof code 5801700 . . . . . . . . . . . 28
2.1.3 For roof tiles code 5801900 . . . . . . . . . . . . . 29
2.1.4 Suspended code 5801500. . . . . . . . . . . . . . . 29
3 MAINTENANCE
30
3.1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4 WARRANTY TERMS AND CONDITIONS AND
LIMITATIONS 30
5 DISPOSAL
31
5.1 Disposal of the equipment (European Directive
2012/19/EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6 SCHEDULE OF INTERVENTIONS
32