– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
NOTE:
holding the buttons
>
or
<
increases the speed of the
scrolling movement.
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
<
to decrease it
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
<
and
o
at the same time
for approximately 5 seconds until the
initial screen is displayed.
7.4
List of parameters
Type
No.
Description
Range
U/M
Step
Default
CONFIGURATION
tS
0.1
Index showing boiler power in kW
0 = 24
1 = 30
-
1
0, 1
tS
0.2
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or
heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
-
1
0
tS
0.3
Gas Type Configuration
0 = G20
1 = G31
-
1
0 or 1
tS
0.4
Combustion configuration
0 = sealed chamber with combustion
control
1 = open chamber with smoke thermo-
stat
2 = low NOx
-
1
0
tS
0.7
Ignition power
0 .. 40
-
1
0
tS
0.8
External sensor value correction
-5 .. +5
°C
1
0
DOMESTIC HOT WATER - HEATING
tS
1.0
Boiler Antifreeze Threshold
0 .. +10
°C
1
3
tS
1.1
External Sensor Antifreeze Threshold
-- = Disabled
-9 .. +5
°C
1
-2
tS
1.2
Heating Curve Incline
0 .. 80
-
1
20
tS
1.3
Minimum Heating Temperature Adjustment
20 .. Par tS 1.4
°C
1
20
tS
1.4
Maximum Heating Temperature Adjustment
Par tS 1.3 .. 80
°C
1
80
tS
1.5
Maximum power heating
0 .. 100
%
1
100
tS
1.6
Heating Post-Circulation Time
0 .. 99
seconds
x 10
1
3
tS
1.7
Heating Pump Activation Delay
0 .. 60
seconds
x 10
1
0
tS
1.8
Re-ignition Delay
0 .. 60
Min
1
3
tS
1.9
Domestic Hot Water Modulation with Flow meter
0 = Disabled
1 = Enabled
-
1
1
tS
2.0
Maximum power domestic hot water
0 .. 100
%
1
100
tS
2.1
Minimum power heating/domestic hot water
(premixed)
0 .. 100
%
1
0
tS
2.2
Domestic hot water preheating enabling
0 = OFF
1 = ON
-
1
0
tS
2.5
Internal parameter (no change)
-
-
-
0
tS
2.6
Zone Valve / Pump Relaunch Delay
0 .. 99
Min
1
1
tS
2.9
Anti-legionella Function (Only hot water tank)
-- = Disabled
50 .. 80
-
1
--
Summary of Contents for 8112100
Page 10: ...10 FR ...
Page 18: ...18 FR ...
Page 43: ...43 FR ...
Page 52: ...52 EN ...
Page 60: ...60 EN ...
Page 85: ...85 EN ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 90: ...43 ة َّ ي العرب ...
Page 115: ...18 ة َّ ي العرب ...
Page 123: ...10 ة َّ ي العرب ...