4.7 BURNER START-UP CYCLE

  Lock out is indicated by a lamp on the control box (3, fig. 1, page 1).

5.

MAINTENANCE

Burner requires a periodic maintenance carried out by a qualified and authorized technicians.
Maintenance is essential for the reliability of the burner, avoiding the excessive consumption of fuel and
consequent pollution.

Before  carrying  out  any  cleaning  or control always first switch off the electrical supply to the
burner acting on the main switch of the system.

THE BASIC CHECKS ARE:

Check that there are not obstructions or dents in the supply or return oil pipes.

Clean the filter in the oil suction line and in the pump.

Clean the 

photoresistance,

 (see fig. 9, page 5).

Check for correct fuel consumption.

Replace the nozzle (see fig. 10, page 6) and check the correct position of electrodes (fig. 11, page 7).

Clean the combustion head in the fuel exit area, on the diffuser disc.

Leave the burner working without interruptions for 10 min. and set rightly all the components stated in
this manual.  Then carry out a combustion check verifying:

Smoke temperature at the chimney;

Content of  CO

2

 ( % );

Content of CO (ppm);

Smoke value according to opacity smokes index according to Bacharach scale.

Thermostat

Heater

Green led and motor

Ignition transformer

Oil valve

Flame

~

120

s

D5927

~

120

s

~

12

s

Lock-out lamp

~

12

s

~

5

s

Lock-out due to failure to light    

 

C

Normal

Orange led

C

Summary of Contents for 8099000

Page 1: ...iften Installation use and maintenance instructions Oil burners Br leurs oul Stookoliebranders CODE MODEL MODELE TYPE 8099000 SIME MACK 3 514 T1R 8099010 SIME MACK 4 515 T3R 8099030 SIME MACK 5 515 T5...

Page 2: ...4...

Page 3: ...aulic systems 4 3 3 Electrical wiring 5 4 WORKING 6 4 1 Combustion adjustment 6 4 2 Nozzles recommended 6 4 3 Electrodes setting 7 4 4 Air damper adjustment 7 4 5 Pump pressure 7 4 6 Fuel heating 7 4...

Page 4: ...7A 2850 rpm 298 rad s Capacitor 4 F Ignition transformer Secondary 8 kV 16 mA Pump Pressure 7 15 bar Absorbed electrical power 0 165 kW 0 185 kW 0 8 0 0 4 Pressure in the combustion chamber mbar Light...

Page 5: ...ng gasket holes 5 Fix the ange 1 to the boiler door 4 using screws 2 and if necessary the nuts 3 interposing the insulating gasket 5 see g 3 Model A B C D E F G MACK 3 268 229 208 86 89 170 10 MACK 4...

Page 6: ...non return valve is required This solution however is less safe than previous one due to the possibility of leakage of the valve It is necessary to install a filter on the fuel supply line The standar...

Page 7: ...shut down of the burner by opening the ther mostats CONTROL BOX To remove the control box from the burner loosen screw A fig 8 and pull to the arrow direction after removing all components the 7 pin p...

Page 8: ...nd room temperature of 20 C BOILER BURNER Nozzle Pump pressure Burner output Air damper adjustment Code Model GPH Angle bar kg h 4 Set point Rond Estelle 3 8099000 MACK 3 0 55 60 S 12 2 1 3 7 Rond Est...

Page 9: ...recommended to proceed as follows Adjust the air damper as indicated in the table Mount the cover Check smoke number and CO2 Should it become necessary to modify the air output remove the cover by loo...

Page 10: ...s Clean the filter in the oil suction line and in the pump Clean the photoresistance see fig 9 page 5 Check for correct fuel consumption Replace the nozzle see fig 10 page 6 and check the correct posi...

Page 11: ...SOLUTION All led are off and the burner does not start Lack of electrical supply Check presence of voltage in the L1 N clamps of the 7 pin plug Check the conditions of the fuses Check that thermostat...

Page 12: ...Fonderie Sime S p A via Garbo 27 37045 Legnago Vr Italy Tel 39 0442 631111 Export Division fax number 39 0442 631293 Sime Service fax number 39 0442 631292...

Reviews: