3
5101153 Rev D
I-VSE 5000
3. SPECIFICATIONS
I-VSE 5000
Operating Voltage
120 or 230 VAC, 50/60 Hz
Power
45 Watts
Dimensions
10”L x 12”W x 6-1/4”H
Weight
8 lb
Blower Output
100 – 255 CFM (Adjustable)
Airspeed Characteristics
850 FPM at 2-ft (fan speed high)
Noise Level
68 dB at high fan speed (2’ from blower)
Typical Discharge Time
0.6 sec at 1-ft (1000V to 100V)
4. INSTALLATION
1.
For maximum effectiveness, position the I-VSE 5000 as close as possible to the
charged surface to be neutralized. Direct the air stream longitudinally, and in the
same direction as, the target material movement to maximize the time the charged
surface remains in the air stream.
2.
Locate blowers after the material has received its static charge. If the material is
subject to ongoing friction, additional static control devices may be needed.
3.
Blowers may be located above and/or below a web.
4.
Ensure that the ionized air stream covers the entire target surface, and that the
material to be neutralized is not in direct contact with a background surface.
5.
The blower may also be placed on an OPTIONAL vertically adjustable floor stand
that can be moved and positioned as required.
6.
The unit MUST be grounded for ionization to occur.