5100460 Rev E

3. INSTALLATION

Mounting and Grounding the Power Supply

The power supply is designed for flat surface mounting and can be easily mounted using 

the mounting flanges at the base of the unit.  The ambient temperature of mounting are of 

the power supply must not exceed 105˚F (40˚C).

WARNING – Electrical Shock Hazard

Failure  to  properly  ground  a  power  supply  may  result  in  an  electrical  shock 

hazard to personnel and inefficient operation of equipment.

Proper grounding of the power supply enclosure is essential for safe and efficient 

operation.  Proper grounding can be accomplished by either of the following methods:

1.  For power supplies mounted on machinery, connect power supply ground stud with 

at least #16 AWG copper wire.

2.  All power supplies are equipped with a 3-conductor line cord.

For power supplies with 120 VAC operating voltage, the line cord is fitted with a standard 

NEMA 5-15P plug.  The line cord must be plugged into a 3-terminal grounded receptacle.

For power supplies with 230 VAC operating voltage, the line cord is fitted with a standard 

NEMA 6-15P plug.  The line cord must be plugged into a 3-terminal grounded receptacle.

For power supplies that are equipped with a plug-less 3-conductor line cord, the ground 

wire (green or green/yellow) must be connected to earth ground.

Input Line Voltage Connections

The line cord must be connected to a power source of the correct voltage and frequency as 

listed on the nameplate.  For power supplies with 120 or 240 VAC operating voltage, the 

line cord is fitted with a plug.  For power supplies with a plug-less line cord, the following 

connections are required:

Wire Colors

North America

International

Power Connection

Black

Brown

Live

White

Blue

Neutral

Green

Green/Yellow

Ground

If the static eliminating equipment is used on machinery, it is recommended that the line 

cord of the power supply be connected to the machine “RUN” button.  This enables the 

static eliminating equipment to turn on and off with the machine.  Some power supplies 

are equipped with an ON/OFF switch with indicator.

Summary of Contents for 4002315

Page 1: ...POWER SUPPLIES 5100460 Rev E Type N Power Supplies INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...RIPTION 2 Receipt of Equipment 2 Return Shipments 2 3 INSTALLATION 3 Mounting and Grounding the Power Supply 3 Input Line Voltage Connections 3 High Voltage Connections for Standard Cable 4 4 OPERATIO...

Page 3: ...erform installation and repairs 3 All equipment must be properly grounded including the machine frame to which the equipment is mounted 4 Do not operate device in excess of specifications NOTE Do not...

Page 4: ...and unit number These numbers are listed on the label affixed to the power supply Line voltage and frequency requirements as well as output ratings are listed on the nameplate The Simco Ion Type N Po...

Page 5: ...rd must be plugged into a 3 terminal grounded receptacle For power supplies with 230 VAC operating voltage the line cord is fitted with a standard NEMA 6 15P plug The line cord must be plugged into a...

Page 6: ...on cutout 4 Cut a suitable high voltage cable to desired length Insert cable through strain relief bushing Allow additional length for cable to reach high voltage output terminal block inside power su...

Page 7: ...5 POWER SUPPLIES 5100460 Rev E Figure 1 Outline Drawings of Type N Power Supplies Figure 2 High Voltage Output Connections of Power Supply...

Page 8: ...quipment is properly installed To operate the static eliminating equipment apply line voltage to the power supply For power supply equipped with an ON OFF switch place the switch in the ON position Al...

Page 9: ...rocedures for Checking the power supply are as follows 1 Disconnect line voltage to power supply 2 Remove lid from power supply 3 Disconnect all static eliminating equipment from power supply s voltag...

Page 10: ...r supply model number and unit number part description part number and quantity The model number and unit number can be found on the label attached to the power supply Model Power Supply Part Xfmr Ass...

Page 11: ...r a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received d...

Page 12: ...10 POWER SUPPLIES 5100460 Rev E Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2017 Simco Ion Printed in the U S A...

Reviews: