background image

 

 

 

ST107 

 

EN 

5

 

Technical specifications 

Operating 

 

Voltage range 

6 - 35 V 

Temperature range 

-20 – 70 °C (-4 – 158 °F)

 

Power consumption at 12 V  

 

Operating 

2.5 mA 

Voltage inputs 

Range 

0 – 35 V 

Resolution 

1 mV 

Accuracy 

± 0.2 % 

Sampling rate 

10 ms 

Resistance inputs 

Range 

10 ohm – 65 kohm 

Accuracy 

± 0.1% 

Sampling rate 

 10 ms 

Dimensions 

112x72x31 mm 

Connectivity 

Up to 

Tank level sensors* 

Temperature sensors** 

SICOM port 

Alarm contact 

 

 

Table 1Technical specifications 

*  Maximal  number  of  connected  tank  sensors  to  one  ST107  digital  tank  module.  This  includes  4  resistance  and  3  voltage 
sensing inputs, which excludes connecting any temperature sensor. 

** Maximal number of connected temperature sensors to one ST107 digital tank module, which excludes connecting any tank 
sensor  

6

 

Trouble shooting 

6.1

 

Tank sensor is not visible on PICO 

If the tank sensor is not visible in PICO’s menu, check the following: 

 

Is the ST107 properly connected via the SiCOM port to the PICO. 

 

If you are using your own SiCOM cable make sure you are using the right one. See 4.2.1 SiCOM data cable. 

6.2

 

Tank sensor is showing the same liquid level for long time 

In case you installed the sensor for the first time, consider checking the following: 

 

Are you using a compatible resistance/voltage tank sensor? Check the requirements in chapter 5 Technical 
specifications. 

 

Is the tank sensor properly installed and working? 

 

Is the tank sensor properly connected to the right resistance or voltage input sensor on ST107?  

 

Is the tank sensor calibrated via PICO’s menu? Each tank sensor needs to be calibrated to show the right level. Check 
PICO’s manual, how to calibrate a tank sensor. 

In case the tank sensor has stopped working, consider checking the following: 

 

Is the tank sensor properly installed and working? In case you are using a floating sensor, it could be stuck. 

 

Consider to recalibrate the tank sensor. 

6.3

 

Tank sensor is showing empty tank 

In case you installed the sensor for the first time, consider checking the following: 

 

Is the tank sensor covering the whole tank level? In case you are using a floating sensor, which is to  short, it can 
happen that the sensor is not detecting any liquid under a specific level. 

 

Consider to recalibrate the tank sensor. 

Summary of Contents for ST107

Page 1: ...E SIMARINE ST107 Digital tank module USERS MANUAL Revision 1 0 SIMARINE d o o Ulica skofa Maksimilijana Drzecnika 6 SI 2000 Maribor Slovenia EU http www simarin net Copyright 2016 Simarine d o o All Rights Reserved ...

Page 2: ...ST107 2 ...

Page 3: ... 4 1 Mounting 4 4 2 Cables 4 4 2 1 SiCOM data cable 4 4 3 Connecting 5 4 4 Wiring diagram 5 5 Technical specifications 6 6 Trouble shooting 6 6 1 Tank sensor is not visible on PICO 6 6 2 Tank sensor is showing the same liquid level for long time 6 6 3 Tank sensor is showing empty tank 6 ...

Page 4: ...mmediately with soap under fresh water for at least 15 minutes and seek medical support immediately CAUTION Do NOT connect anything to a damaged battery It could heat up catch fire or explode CAUTION Lead acid Batteries can generate explosive gases during operation Never smoke allow flames or sparks near the battery Make sure to keep sufficient ventilation around the battery CAUTION When working w...

Page 5: ...temperature sensors to ST107 via the resistance or voltage sensing input 3 Connect the alarm contact to execute specific operation on an alarm Each connected liquid or temperature sensor needs to be configured and calibrated This is done via PICO in an easy way The configuration and calibration process is described in PICO s manual To fire the alarm contact it is necessary to configure it via PICO...

Page 6: ...e using the right one See 4 2 1 SiCOM data cable 6 2 Tank sensor is showing the same liquid level for long time In case you installed the sensor for the first time consider checking the following Are you using a compatible resistance voltage tank sensor Check the requirements in chapter 5 Technical specifications Is the tank sensor properly installed and working Is the tank sensor properly connect...

Page 7: ...ung 8 4 1 Befestigung 8 4 2 Verdrahtung 9 4 3 Verdrahtungsdiagramm 9 5 Technische Einzelheiten 10 6 Fehler Beseitigung 10 6 1 Tank Sensor ist nicht sichtbar auf dem PICO 10 6 2 Tank Sensor zeigt den gleichen tank stand für längere zeit 10 6 3 Tank Sensor zeigt einen leeren tank 10 ...

Page 8: ... Kleidung kommt waschen Sie sie sofort mit Seife unter Süßwasser für mindestens 15 Minuten und sofort medizinische Unterstützung suchen VORSICHT Schließen Sie NICHTS an eine beschädigte Batterie an Sie könnte aufheizen Feuer fangen oder explodieren VORSICHT Blei Säure Batterien können während des Betriebs explosive Gase erzeugen Rauchen Sie niemals in der Nähe der Batterie Achten Sie darauf dass e...

Page 9: ...mit Simarine PICO 2 Verbinden Sie jeden kompatiblen Tank oder Temperatursensor über den Widerstand oder Spannung Eingang mit dem ST107 Jeder korrekt angeschlossene Tank oder Temperatursensor muss konfiguriert und kalibriert werden Dies geschieht über PICO auf einfache Weise Die Konfiguration ist im PICO Handbuch beschrieben 4 3 Verdrahtungsdiagramm Bild 2 ST107 Verdrahtungsdiagram ...

Page 10: ...p benutzen 6 2 Tank Sensor zeigt den gleichen tank stand für längere zeit Falls Sie den Tank Sensor zum ersten Mal installiert haben sollten Sie Folgendes prüfen Verwenden Sie einen kompatiblen Widerstand Spannung Tank Sensor Prüfen Sie die Anforderungen im Kapitel 5 Technische Einzelheiten Ist der Tanksensor ordnungsgemäß installiert und funktioniert Ist der Tanksensor am richtigen Widerstands od...

Page 11: ...iCOM 1A data resist temp resist temp Note COM COM NC NO alternative Common GND Battery bank only voltage or TANK with VOLTAGE level sensor 0 35V DC Up to 3 units or TANK with RESISTANCE level sensor 0 65kOHM TEMPERATURE sensor NTC 10kOHM 15 90 C Up to 4 units to another SiCOM port Accessory main switch ...

Reviews: