![Sim2 Teatro SVD 500 PLUS User And Installation Manual Download Page 36](http://html1.mh-extra.com/html/sim2/teatro-svd-500-plus/teatro-svd-500-plus_user-and-installation-manual_1274442036.webp)
SVP 450 PLUS - SVD 500 PLUS
35
ENGLISHENGLISHENGLISHENGLISHENGLISH
CONV CENT
CRT : RGB
ADJ : R . .
H. = 52
V. = 50
b
b
a
a
CONV LIN
CRT : RGB
ADJ : R . .
H. = 45
V. = 50
5.13.1 Central convergence
This function allows to overlap the blue and red
images on the green one, at the centre of the screen.
Press
CONV
. The following menu will appear:
Use the buttons
R,G, and B,
to switch on/off the tubes.
The
CRT
message:
RGB
shows which tubes are on. Use
the buttons
Rsel, Gsel, Bsel,
to select on which tube you
wish to act. The
ADJ
message
: R.
indicates on which
tube you are acting. Press
ENTER
o
EXIT
to change
adjustment.
Press
ESC
to exit.
5.13.2 Convergence linearity
This function is used to modify the distance between
the cross hatch lines until they are equal.
Use the arrow or to change the vertical linearity, and
the arrow or for the horizontal one.
5.13.3 Convergence sizes
This function allows to re-size the image dimensions
for the blue and red CRTs.
CONV SIZE
CRT : RGB
ADJ : R . .
H. = 80
V. = 50
Use the
R,G,B,
buttons to switch on or off the tubes.
The
CRT
message:
RGB
indicates which tubes are
switched on. Use the
Rsel, Gsel, Bsel,
buttons to select
on which tube you wish to act. The
ADJ
message
: R.
indicates on which tube you are acting. Press
ENTER
or
EXIT
to change adjustment.
Press
ESC
to exit.
5.13.4 Convergence skew
This function allows to setup the transversal
horizontal and vertical inclination.
CONV SKEW
CRT : RGB
ADJ : R . .
H. = 48
V. = 50
Use the
R,G,B,
buttons to switch on or off the tubes.
The
CRT
message:
RGB
indicates which tubes are
switched on. Use the
Rsel, Gsel, Bsel,
buttons to select
tube you wish to act. The
ADJ
message
: R.
indicates on
which tube you are acting. Press
ENTER
or
EXIT
to
change adjustment.
Press
ESC
to exit.
5.13.5 Convergence bow
This function allows to setup the horizontal and
vertical curving.
CONV BOW
CRT : RGB
ADJ : R . .
H. = 52
V. = 50
Use the
R,G,B,
buttons to switch on or off the tubes.
The
CRT
message:
RGB
indicates which tubes are
switched on. Use the
Rsel, Gsel, Bsel,
buttons to select
tube you wish to act. The
ADJ
message
: R.
indicates on
which tube you are acting. Press
ENTER
or
EXIT
to
change adjustment.
Press
ESC
to exit.