![Sim2 M.120 User Manual Download Page 18](http://html1.mh-extra.com/html/sim2/m-120/m-120_user-manual_1274354018.webp)
3.Once the emitter is connected to the projector, please make sure that the projector
is in 3D mode. Check the X sign on the emitter; the red light should be on, indicating
that the emitter is functioning.
3D Glasses
Proximity Association with 3D RF emitter
The following procedure has to be done every time the glasses are introduced to new
3D RF emitter. During the proximity association, 3D glasses shall be located within 1 m
from 3D RF emitter.
Switch on the glasses (1 short press on the button). LED will change from off to bright,
indicating glasses power on.
Press button for minimum of 1 second.
After 1 second, LED will start to blink with a rate of 1 blink per 2 second.
Release the button.
Successful proximity association is indicated with 6 short LED blinks.
If glasses could not proximity associate LED will change from bright to off and
glasses will go in power off state.
Connecting glasses to 3D RF emitter
Once glasses are associated with the emitter, they will automatically connect to that
emitter every time they are switched on. If during the operation glasses lost the
connection to the emitter, they will automatically try to reconnect to that emitter (LED
is blinking with a rate of 1 blink per 2 seconds). If glasses cannot successfully
reconnect to the emitter within 60 seconds, LED will change from bright to off and
glasses will automatically go in power off state.
Indicating the battery state
If LED flashes every couple of seconds during the operation, battery level is low.
Charging is indicated with lit LED.
Charging the battery
The glasses are shipped with the micro USB to USB Type A cable. To charge the glasses
battery, plug the micro USB cable in a computer or other USB device capable of
supplying power. LED will remain lit while glasses are charging. When battery is fully
charged LED will go off.
For more information on glasses status and transitions, refer to “3D Glasses” on page
21.
Distances from glasses to 3D RF Emitter
The minimun distance from glasses to 3D RF Emitter is 10 m, the maximun depends
on how the room is made.
AC Power
Choose the AC power cord that is appropriate in your area among those shipped with
the product. Plug the female end of the power cord to the AC receptacle located on
the rear of the projector (100-240 V AC, 50-60 Hz) and the other end into a grounded
AC outlet. An high-quality surge protector is recommended while a UPS is optional.
3
Installation
M.120
User Guide
18