SIM2 DOMINO 55M
RS-232C CONTROL SPECIFICATIONS
(1)
Returned value is indeterminate when the unit is in No Signal state.
Returned value may be different from the value displayed on the OSD, as in the latter, the values have
been normalized to the 0-100 range.
(2)
Returned value is valid only when Video, S-Video, RGBS 15 kHz, YCrCb 15 kHz or YcrCb 32 kHz
signals are displayed. Returned value is indeterminate when other signals are displayed and when the
unit is in No Signal state.
(3)
Returned value is valid only when Video (NTSC), S-Video (NTSC), RGBS 15 kHz, YCrCb 15 kHz
signals are displayed. Returned value is indeterminate when other signals are displayed and when the
unit is in No Signal state.
(4)
Table below associates OSD labels with returned values:
Color Temperature
OSD
Label
Returned
value
High
24
Medium
25
Low
26
User
27
(5)
Table below associates OSD labels with returned values:
Gamma
OSD
Label
Returned
value
Film
10
Film 1
0B
Video
0D
Video 1
0F
Graphics
0C
(6)
Table below associates OSD labels with returned values:
Memory
OSD
Label
Returned
value
0 (Auto)
00
1
01
2
02
3
03
5. Examples
1. Send the simulated "SWITCH ON FROM STAND-BY AND SELECT SOURCE" Remote Control
keycode.
Remote Control allows Switching on from Stand-by via one of the keys "1", "2" ... "7".
Send, for instance, the code relative to key "1":
BEEF02060080E5490100000000.
The DOMINO 55M switches on and selects Input 1.
The DOMINO 55M returns the response code:
06
(Acknowledged with no error).
NOTE: Commands that simulate keys "1", "2" ... "7" switch on the unit and select the corresponding
Source.