SIM2 DOMINO 20H / DOMINO 30H
RS-232C CONTROL SPECIFICATIONS
10
3. Send the "SET ASPECT ANAMORPHIC" Operation Code.
Send the packet:
BEEF0206009DF5840100000000.
The Aspect Ratio changes to Anamorphic.
The projector returns the response code:
06
(Acknowledged with no error).
4. Select "INPUT 3 (COMP. RGB) WITH YcrCb 15kHz SIGNAL"
Send the packet:
BEEF0319005B0C01820800000000000008000000000000000000000000000000
Wait for the return code and add an additional delay of 40 ms.
Send the the code relative to the Key to which Input 3 has been assigned: for instance if the key is "3"
the code is:
BEEF02060062E44B0100000000
6. Warnings
When the number of bytes sent to the Projector is greater than indicated for the Command (32 bytes for
Operation Packets and 13 bytes for Event Packets), excess data will be ignored.
Conversely, if number of bytes sent to the Projector is smaller than required by the Communication Protocol,
an Error Code will be returned.
Allow a time interval of at least 40 ms between the Return Code and the following Command.