background image

 

SIM2 DOMINO 20H / DOMINO 30H 

RS-232C CONTROL SPECIFICATIONS

 

 

10

3.  Send the "SET ASPECT ANAMORPHIC" Operation Code. 

Send the packet: 

BEEF0206009DF5840100000000.

 

The Aspect Ratio changes to Anamorphic. 
The projector returns the response code:

06

(Acknowledged with no error). 

 

4.  Select "INPUT 3 (COMP. RGB) WITH YcrCb 15kHz SIGNAL"  

Send the packet: 

BEEF0319005B0C01820800000000000008000000000000000000000000000000

Wait for the return code and add an additional delay of 40 ms. 
Send the the code relative to the Key to which Input 3 has been assigned: for instance if the key is "3" 
the code is: 

BEEF02060062E44B0100000000

 

 

6. Warnings 

 
When the number of bytes sent to the Projector is greater than indicated for the Command (32 bytes for 

Operation Packets and 13 bytes for Event Packets), excess data will be ignored.  
Conversely, if number of bytes sent to the Projector is smaller than required by the Communication Protocol, 

an Error Code will be returned.  
Allow a time interval of at least 40 ms between the Return Code and the following Command.

Summary of Contents for DLP RS-232C

Page 1: ...DOMINO 20H DOMINO 30H DLP VIDEO PROJECTOR RS 232C CONTROL SPECIFICATIONS Document Revision 1 1 20 July 2004...

Page 2: ...NICATION PROTOCOL 4 HEADER 4 PAYLOAD 4 4 COMMANDS 5 REMOTE CONTROL KEYCODES 5 OPERATION CODES 7 5 EXAMPLES 9 6 WARNINGS 10 Revision History Revision Date Software Version Description of Change 1 1 20...

Page 3: ...5 SIM2 DOMINO 20H DOMINO 30H RS 232C Port is described as follows SIM2 DOMINO 20H DOMINO 30H RS 232C Control Port Pin No Signal Definition 1 N A Not used 2 TD Transmit data 3 RD Receive data 4 N A No...

Page 4: ...Header size is fixed at seven bytes 0 1 2 3 4 5 6 BE EF Packet Type Packet Payload Size Packet Checksum CRC 0xEFBE is a fixed value that is used to insure packet alignment if there are partial packet...

Page 5: ...01 00 00 00 00 CURSOR LEFT BE EF 02 06 00 EF E7 56 01 00 00 00 00 CURSOR RIGHT BE EF 02 06 00 3E E6 57 01 00 00 00 00 CURSOR DOWN BE EF 02 06 00 C1 E6 58 01 00 00 00 00 MENU LEFT BE EF 02 06 00 10 E7...

Page 6: ...F 01 00 00 00 00 Goto Color BE EF 02 06 00 19 F4 80 01 00 00 00 00 Goto Tint BE EF 02 06 00 C8 F5 81 01 00 00 00 00 1 When the unit is in Stand by state this command switches on the unit and the last...

Page 7: ...FILTER DECREMENT BE EF 03 19 00 BA 6E 04 09 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SET VIDEO BE EF 03 19 00 7A 80 01 60 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0...

Page 8: ...00 SET VIDEO BE EF 03 19 00 C8 1B 01 27 08 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 GAMMA SET GRAPHICS BE EF 03 19 00 39 5B 01 27 08 00 00 00 00 00 00 02 00 00 00 00 00 00 00...

Page 9: ...08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SET YCrCb AutoSync BE EF 03 19 00 92 04 01 82 08 00 00 00 00 00 00 14 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SET YCrCb 15kHz...

Page 10: ...eturn code and add an additional delay of 40 ms Send the the code relative to the Key to which Input 3 has been assigned for instance if the key is 3 the code is BEEF02060062E44B0100000000 6 Warnings...

Reviews: