![Silvertel Ag102 User Manual Download Page 4](http://html1.mh-extra.com/html/silvertel/ag102/ag102_user-manual_1274247004.webp)
Ag102 Evaluation Board User Manual
3
4.2 Output
The output connections to the SLA battery are made through J1 (positive) and J11
(negative). The output current can be measure by removing LK2 and connecting an
ammeter across these pin.
4.3 Capacity Selection
The EVALAg1x2 evaluation board can set the Ag102 capacity from 1.2Ah to 7Ah by
setting the corresponding jumper link on J6 (see Figure 2 and Table 1).
Figure 2: Capacity selection link
J6 Resistor
Selection
R
CS
Resistance
(Ohms ±1%)
Battery
Capacity (Ah)
Min Input
Voltage (V)
Bulk Charge Current
Limit (A) ±10%
R3 1K 1.2 9
0.3
R4 2K7 2 9
0.5
R5 4K3 2.1 9
0.525
R6 6K8 2.3 9
0.575
R7 10K 2.8 9
0.7
R8 15K 3.2 12
0.8
R9 24K 4 12
1
R10 43K
7 12
1
Table 1: Output Connections
Note: to prevent damaging the battery it is important that the correct value of RCS is set. If the selector link is not fitted, then the
Ag102 will default to 1.2Ah capacity.