03
1.Maximum continuous total DC output power should not exceed 1000W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 83A (996W).
4.Maximum peak total DC output power should not exceed 1100W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
1.Maximum continuous total DC output power should not exceed 850W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 70A (840W).
4.Maximum peak total DC output power should not exceed 950W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
2.2.3: (ST1000-G Load Range)
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Min
0.3
0.3
0.1
0
0.1
Max
25
25
83
0.3
3.5
Unit
Amps
Amps
Amps
Amps
Amps
1.Maximum continuous total DC output power should not exceed 1200W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 100A (1200W).
4.Maximum peak total DC output power should not exceed 1300W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
2.2.4: (ST1200-G Load Range)
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Min
0.3
0.3
0.1
0
0.1
Max
25
25
100
0.3
3.5
Unit
Amps
Amps
Amps
Amps
Amps
04
STRIDER ST1000
STRIDER ST1000-NV
STRIDER GOLD SERIES
AC H o t
AC N e u tra l
Power Supply
V o u t
V re tu rn
1 0 u F
0 .1 u F
L o a d
S c o p e
AC G ro u n d
The ripple voltage of the outputs shall be measured at the pins of the output connector
when terminated in the load impedance specified in figure 1. Ripple and noise are
measured at the connectors with a 0.1uF ceramic capa ny condition of line voltage,
output load, line frequency, operation temperature.
Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value,
all outputs shall be within the regulation limit of section 2.0 before issuing the power
good signal of section 5.0 .
2.3 Output Ripple
2.4 Overshoot
2.3.1 Ripple regulation
2.3.2 Definition
2.3.3 Ripple voltage test circuit
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Ripple&Noise
<50
<50
<120
<120
<50
Unit
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p