background image

03

1.Maximum continuous total DC output power should not exceed 1000W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not 
   exceed 150W.
3.Maximum current for +12V outputs shall be 83A (996W).
4.Maximum peak total DC output power should not exceed 1100W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.

1.Maximum continuous total DC output power should not exceed 850W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not 
   exceed 150W.
3.Maximum current for +12V outputs shall be 70A (840W).
4.Maximum peak total DC output power should not exceed 950W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.

2.2.3: (ST1000-G Load Range)

Parameter

+3.3V

+5V

+12V

-12V

+5VSB

Min

0.3

0.3

0.1

0

0.1

Max

25

25

83

0.3

3.5

Unit

Amps

Amps

Amps

Amps

Amps

1.Maximum continuous total DC output power should not exceed 1200W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not 
   exceed 150W.
3.Maximum current for +12V outputs shall be 100A (1200W).
4.Maximum peak total DC output power should not exceed 1300W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.

2.2.4: (ST1200-G Load Range)

Parameter

+3.3V

+5V

+12V

-12V

+5VSB

Min

0.3

0.3

0.1

0

0.1

Max

25

25

100

0.3

3.5

Unit

Amps

Amps

Amps

Amps

Amps

04

STRIDER ST1000

STRIDER ST1000-NV

STRIDER GOLD SERIES

AC  H o t

AC  N e u tra l

Power Supply

V o u t

V re tu rn

1 0 u F

0 .1 u F

L o a d

S c o p e

AC  G ro u n d

The ripple voltage of the outputs shall be measured at the pins of the output connector 
when terminated in the load impedance specified in figure 1. Ripple and noise are 
measured at the connectors with a 0.1uF ceramic capa ny condition of line voltage, 
output load, line frequency, operation temperature.

Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value, 
all outputs shall  be within the regulation limit of section 2.0 before issuing the power 
good signal of section 5.0 .

2.3 Output Ripple

2.4 Overshoot

2.3.1 Ripple regulation

2.3.2 Definition

2.3.3 Ripple voltage test circuit

Parameter

+3.3V

+5V

+12V

-12V

+5VSB

Ripple&Noise

<50

<50

<120

<120

<50

Unit

mVp-p

mVp-p

mVp-p

mVp-p

mVp-p

Summary of Contents for SST-ST1200-G

Page 1: ...October 2010 NO G11212840 STRIDER GOLD ST1200 G ST1000 G ST85F G ST75F G The perfect balance of performance efficiency and quality ...

Page 2: ...ut fuse bulk rectifiers and surge limiting device Parameter Vin Full range Vin Full range 1200W Vin Frequency Iin 750W Iin 850W Iin 1000W 1200W Min 90 103 47 Nom 100 240 115 240 60 50 9 5 4 8 11 5 5 12 6 Max 264 264 63 Unit VACrms VACrms Hz Arms Arms Arms 02 STRIDER GOLD SERIES 2 DC OUTPUT 2 1 DC voltage regulation 1 Maximum continuous total DC output power should not exceed 750W 2 Maximum continu...

Page 3: ...hall not exceed 150W 3 Maximum current for 12V outputs shall be 100A 1200W 4 Maximum peak total DC output power should not exceed 1300W 5 Peak power and current loading shall be supported for a minimum of 12 second 6 When 12V is load to 28A 12V minimum load is 0 02A 2 2 4 ST1200 G Load Range Parameter 3 3V 5V 12V 12V 5VSB Min 0 3 0 3 0 1 0 0 1 Max 25 25 100 0 3 3 5 Unit Amps Amps Amps Amps Amps 04...

Page 4: ...t Volts Volts Volts The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machine 3 2 Over power protection The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machin...

Page 5: ...UIREMENTS The power supply designed to meet UL 1950 If applicable to sales in Japan or Europe the power supply shall meet the requirements of EN 61000 3 2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full rated power 6 1 Underwriters Laboratory UL recognition The demonstrated MTBF shall be 100 000 h...

Page 6: ...ck Black ATX 12V 4PIN 4 4PIN EPS 12V in split mode Black Black Signal GND GND Pin 1 2 Pin 3 4 Signal 12V 12V Yellow Yellow 9 2 Connectors 10 STRIDER GOLD SERIES SATA connector Orange Black Red Black Yellow Signal 3 3V COM 5V COM 12V Pin 5 4 3 2 1 8PIN PCI Express connector Yellow Yellow Yellow Black sense1 Signal 12V 12V 12V COM Pin 1 2 3 4 Pin 5 6 7 8 Signal COM COM COM COM Black Black Black Blac...