background image

- 2 -

CLOCK RADIO 
KH 2189

Intended use

The intended uses for this device are the reception
of FM / AM radio transmissions and as a wakeup
alarm, using signal tones or the radio itself. 
This device is intended for use only in domestic settings.
It is not suitable for use in commercial or industrial
applications.

Technical data

This device complies with the fundamental require-
ments and other relevant stipulations of the EMC 
Directive 2004/108/EC, as well as the Guidelines
of the Low Voltage Directive 2006/95/EC.

Mains voltage:

220 - 240 V ~ / 50 Hz

Back-up power :

9 V Block battery 
Type 6LR61/6F22 
(Not supplied)

Power consumption:

5 W

Power consumption
Standby:

max. 3 W

Protection class:

II / 

Radio frequency range: 

FM (VHF) :

87,5 

108 MHz

AM (MW) :

526,5 

– 

1606,5 kHz

The technical capabilities of this device make possible
an adjustable frequency range that lies beyond the
permitted frequency ranges of 87,5 – 108 MHz and
526,5 – 1606,5 kHz. In some countries, different
national regulations may apply in regard to the assig-
ned radio frequency ranges. Note that information
received from transmissions outside the assigned 
radio frequency ranges may not be exploited, passed
on to third parties or otherwise improperly misused.

Alarm functions :

Radio, alarm signal

Operating temperature 
range:

+5° - +35°C

Humidity:

5 — 90% 
(no condensation)

Dimensions:

15,2 x 7,2 x 8,5 cm

Weight :.

ca. 415 g

Delivery Contents

Radio Alarm
Operating Instructions

Safety instructions

• This device is not intended for use by individuals 

(including children) with restricted physical, physio-
logical or intellectual abilities or deficiences in
experience and/or knowledge unless they are
supervised by a person responsible for their safety
or receive from this person instruction in how the
device is to be used. 

• Children should be supervised to ensure that

they do not play with the device.

• Keep batteries away from children. Children can

put batteries into their mouths and swallow them.
If a battery is swallowed medical assistance must
be sought IMMEDIATELY.

To avoid potentially fatal electric
shocks:

• Connect the device only to correctly installed

and earthed mains sockets. Ensure that the rating
of the local power supply tallies completely with
the details given on the rating plate of the device.

• Make sure that the power cable never becomes

wet or damp during operation. Lay the cable such
that it cannot be trapped or otherwise damaged. 

IB_KH2189_DT35278_LB6  30.07.2009  8:54 Uhr  Seite 2

Summary of Contents for KH 2189

Page 1: ...KOMPERNASS GMBH BURGSTRASSE 21 D 44867 BOCHUM www kompernass com ID Nr KH2189 07 09 V2 6 KH 2189 CLOCK RADIO Clock Radio Operating instructions CV_KH2189_DT35278_LB6 qxd 30 07 2009 13 33 Uhr Seite 1 ...

Page 2: ...KH 2189 j h g q w e f d D A B C y u i o a s r t CV_KH2189_DT35278_LB6 qxd 30 07 2009 13 33 Uhr Seite 4 ...

Page 3: ...ption 5 Setting the alarm time 5 Switching the alarm function on 5 Switching the alarm function off 6 Sleep Timer 6 Cleaning and Care 6 Disposal 6 Importer 7 Warranty Service 7 Read these operating instructions carefully before using this device for the first time and preserve this manual for later reference Pass this manual on to whoever might acquire the device at a future date ...

Page 4: ... assigned radio frequency ranges may not be exploited passed on to third parties or otherwise improperly misused Alarm functions Radio alarm signal Operating temperature range 5 35 C Humidity 5 90 no condensation Dimensions 15 2 x 7 2 x 8 5 cm Weight ca 415 g Delivery Contents Radio Alarm Operating Instructions Safety instructions This device is not intended for use by individuals including childr...

Page 5: ...lug MUST be removed from the wall socket Interaction with batteries For safe interaction with batteries please observe the following safety instructions Do NOT throw the battery into a fire Do NOT short circuit the battery Do NOT attempt to recharge the battery Regularly check the condition of the battery Leaked battery acid can cause permanent damage to the appliance Exercise especial care when d...

Page 6: ... Volume regulator Commissioning Setup Unpack the radio alarm and all ancillaries Remove all transport restraints and adhesive tape films Attention Do not permit small children to play with the plastic packaging There is a risk of suffocation Position the radio alarm on a level and horizontal surface Inserting the batteries Power cut protection Through the insertion of a 9 V block battery Type 6LR6...

Page 7: ...slowly move and hold the end of the wire aerial e in various directions When you have found the best reception for the desired transmitter fix the wire aerial into this position e g with adhesive tape For the reception of AM transmitters an aerial is built into the device For improved reception alter the position of the device in radio mode Setting the alarm time When the correct time has been pro...

Page 8: ...ctivated By pressing the button SLEEP i once again the switch off time reverts to 59 minutes Cleaning and Care Attention Risk of electric shock Before cleaning the device Disconnect the power plug from the power socket NEVER open the housing of the device There are no user serviceable elements inside Clean the device only with a lightly moistened cloth Do not use detergents or solvents They can da...

Page 9: ...ds be assured The warranty covers only claims for material and maufacturing defects not for wearing parts or for da mage to fragile components This product is for priva te use only and is not intended for commercial use The warranty is void in the case of abusive and im proper handling use of force and internal tampering not carried out by our authorized service branch Your statutory rights are no...