SilverCloud SC-UF41 User Manual Download Page 7

2

Configuration:

Display symbols:

Taking a measurement:

BODY

Forehead measuring mode
Ambient measuring mode  

Centigrade          
Fahrenheit

Low battery
Memory

Alarm beep signal

          

 

M

SURFACE TEMP

ú

Install battery 

ú

For the first use or when inserting new batteries, wait 
10 minutes for the warming-up of the device.

ú

Aim towards the forehead as the picture shows, from 
a  distance  of  5~10cm,  press  the  scan  button  and 
measured data will be immediately displayed on the 
LCD. Make sure there is no air perspiration, cosmetic 
or cap covered on forehead. When there is sweat on 
forehead  you  can  measure  behind  the  ear  lobe 
making sure no hair, sweater or other things cover the 
ear. 

ú

Memory recall: Press “M” button to consult measured 
result

ú

Battery  replacement:  When  LCD  shows  low  battery 
symbol          it means you must install new batteries. 
Remove the battery compartment cover and put 2AA 
(1.5 volt) batteries (alkaline batteries) paying attention 
to the polarity. 

Summary of Contents for SC-UF41

Page 1: ...Termometru digital SilverCloud UF41 cu tehnologie infrarosu non contact pentru corp si suprafete MANUAL DE UTILIZARE...

Page 2: ...va aparea simbolul Lo Daca aparatul este setat pe modul SURFACE TEMP pe ecran va aparea direct temperatura masurata ultima data cand a fost folosit acest mod Pentru a obtine un rezultat precis in cazu...

Page 3: ...e dupa cum vedeti in imaginea alaturata la o distanta de 5 10 cm apasati butonul SCAN Rezultatul va a sat imediat pe ecran Asigurati va ca persoana analizata nu este transpirata nu are produse cosmeti...

Page 4: ...par sau de transpiratie 2 Va a ati intr o zona in care sunt curenti de aer care interfereaza cu uxul IR 3 Perioada dintre doua masuratori este prea mica 4 Distanta dintre termometru si corp este mai m...

Page 5: ...Non contact Infrared Thermometer SilverCloud UF41 for body and ambient USER MANUAL...

Page 6: ...ode is BODY last time you used the LCD maybe display Lo if the mode is SURFACE TEMP last time you used the LCD will show the measured result In order to obtain reliable and stable results when changin...

Page 7: ...10cm press the scan button and measured data will be immediately displayed on the LCD Make sure there is no air perspiration cosmetic or cap covered on forehead When there is sweat on forehead you ca...

Page 8: ...he IR ow 3 Temperature readings are too close together to make the body temperature have chance to boot itself 4 The measuring distance if too far Trouble shooting Icons description Speci cation Norma...

Reviews: