After satisfying the installation requirements, the unit is ready to start.  The unit will start when the power cord is connected to the 
required power source.  If the compressor does not start when the unit is initially plugged in, check to make sure that the 

temperature control is not in the ‘off ‘ position.  Allow the unit to run a minimum of two hours before loading it with product.  

 

Temperature Control 

The Temperature Control is located on the compressor end of the unit.  To obtain colder temperatures turn the Temperature Control 

knob clockwise and visa versa.  Allow the unit a minimum of two hours to respond to a control setting adjustment. 

 

Defrost

 

Your Silver King unit is a manual defrost unit.  It should be defrosted whenever the walls accumulate a frost layer that is ¼ inch 

thick.  To defrost the unit, either turn the Temperature Control stem to the “off” position (fully counterclockwise) or disconnect the 

power from the electrical receptacle and remove the pans.  After the frost has melted or come loose from the walls, wipe out the 

cabinet interior.  Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit. 
 

MAINTENANCE

 

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 

the appliance. 
 

Cabinet Surfaces 

The cabinet interior is aluminum and the exterior is stainless steel.  These surfaces should be cleaned periodically with a solution of 

warm water and mild soap, rinsed with clean water and wiped dry with a soft cloth.  A stainless steel cleaner can also be used.  
Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad.  Use a soft cleanser and rub 

with the grain of the metal to avoid scratching the surface.  Do not use chlorinated cleaners. 

 

Pumps

 

To maintain the operation of the Pumps they should be disassembled and cleaned inside and out regularly.   To do so, first remove 

the Pump from the Jar and immerse it in hot soapy water while operating the pump to purge the product that is inside of it.  Repeat 

with clean water once the inside of the pump has been thoroughly purged.  To disassemble the pump, refer to the parts list supplied 

for a complete breakdown of the Pumps. 
    

Condenser

 

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the 

dust, blow air though the condenser fins or remove the end panel and brush the dust from the backside of the condenser. 

 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Summary of Contents for SKRCF

Page 1: ...1 Specifications Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Technical Manual and ReplacementPartsList CounterTop Fountainette MODEL SKRCF ...

Page 2: ...ill need to be performed periodically to keep the Pumps operating properly and to keep them sanitary Location When locating your new Silver King unit convenience and accessibility are important considerations but the following installation guidelines must be observed Always avoid locating the unit adjacent to an oven heating element or hot air source which could adversely affect the performance of...

Page 3: ...nit MAINTENANCE Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of the appliance Cabinet Surfaces The cabinet interior is aluminum and the exterior is stainless steel These surfaces should be cleaned periodically with a solution of warm water and mild soap rinsed with clean water and wiped dry with a soft cloth A stainl...

Page 4: ...iene de las Bombas Ubicación Al elegir una ubicación para su nueva unidad Silver King debe tener en cuenta la conveniencia y facilidad de acceso pero debe seguir las siguientes pautas de instalación Siempre evite colocar la unidad cerca de un horno elemento calefactor o fuente de aire caliente quepueda afectar el funcionamiento de la unidad Para lograr una ventilación adecuada deje un espacio de a...

Page 5: ...ANTENIMIENTO El mantenimiento preventivo es mínimo aunque estos pocos pasos son muy importantes para que la unidad siga funcionando y para maximizar la vida útil del artefacto Superficies del Gabinete El interior del gabinete es de aluminio y acero inoxidable y el exterior es de acero inoxidable Debe limpiar las superficies en forma periódica con una solución de agua tibia y jabón suave luego enju...

Page 6: ...ura besoin d être exécutée périodiquement pour conserver les pompes dans un état de fonctionnement correct et hygiénique Emplacement Quand vous déterminez l emplacement de votre Modèle SKRCF la commodité et l accessibilité sont des considérations importantes mais les conseils d installation qui suivent doivent être observés Évitez toujours de placer le réfrigérateur dans le voisinage d un four d u...

Page 7: ...TIEN L entretien préventif est minimal bien que les quelques mesures qui suivent soient très importantes pour un fonctionnement continu et pour maximiser la durée de vie de l appareil Surfaces de l armoire L intérieur de l armoire est en aluminium et l extérieur est en acier inoxydable Ces surfaces doivent être nettoyées périodiquement avec une solution de savon doux dans l eau chaude rincées avec...

Page 8: ...gelmäßig durchgeführt werden damit die Pumpen ordnungsgemäß funktionieren und die Hygiene gewährleistet ist Aufstellort Für die Wahl des Aufstellortes Ihres Modells SKRCF sind Bequemlichkeit und Zugänglichkeit wichtige Kriterien folgendes muss jedoch beachtet werden Stellen Sie das Gerät nie direkt neben eine Wärmequelle wie einen Herd oder Heizkörper denn dies würde die Funktionsfähigkeit des Ger...

Page 9: ...nimale vorbeugende Wartung doch diese wenigen Schritte sind sehr wichtig um den Betrieb zu gewährleisten und die Lebensdauer des Gerätes zu verlängern Schrankoberflächen Das Schrankinnere ist aus Aluminium und das Äußere aus Edelstahl Diese Oberflächen sollten regelmäßig mit warmem Seifenwasser gereinigt mit klarem Wasser abgespült und mit einem weichen Tuch trocken gewischt werden Dazu kann auch ...

Page 10: ...9 ...

Page 11: ...10 ...

Page 12: ...0343 03 COMPRESSOR 230V 10343 24 ELECTRICAL KIT 115V RELAY OVERLOAD CAPACITOR 10344 03 ELECTRICAL KIT 230V RELAY OVERLOAD CAPACITOR 10344 24 14 GROMMET COMPRESSOR MOUNT 20363 15 HAIRPIN CLIP 98106 16 COMPRESSOR CHORD 23289 17 DRIER 22677 19 PUMP SYRUP 29430 20 JAR SYRUP 3 5 QT 29431 21 COVER WITH LADEL 29433 22 JAR SYRUP 2 5 QT 29434 23 END PANEL 63124 24 THERMOMETER 99449 11 10 1 4 9 REPLACEMENT ...

Page 13: ...12 FORM NO 25983 REV D ...

Reviews: