Electrical Connections 
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The 
specifications on the data plate supersede any future discussion. 
 
The  standard  refrigerator  is  equipped  with  an  eight  (8)  foot  power  cord  that  requires  a  115  Volt,  60  Cycle,  1  Phase  properly 
grounded  electrical  receptacle.  The  power  cord  comes  with  a  3  prong  plug  for  grounding  purposes.  Any  attempt  to  cut  off  the 
grounding spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and 
could result in serious injury. 
 
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an 
extension cord. 
         
OPERATION 
Initial start up
 
After  satisfying  the  installation  requirements,  the  refrigerator  is  ready  to  start.  The  Compressor  will  start  when  the  power  cord  is 
connected to the required power source. If the Compressor does not start when the unit is initially plugged in, check to make sure 
that  the  Temperature  Control  is  not  in  the  off  position.  Allow  the  unit  to  run  for  two  hours  before  loading  it  with  product.  When 
loading the unit with product, take care not to block the air flow in the cabinet as this would affect the units performance. 
 
Temperature Control 
The  Temperature  Control  is  located  on  the  back  of  the  cabinet  and  is  factory  set  to  maintain  an  average  cabinet  temperature  of 
approximately 38 Deg F.  To obtain colder temperatures, press and hold the set button until the set point value flashes.  Use the up 
or down arrow buttons to change the value and then press the set button again.  Allow the unit a minimum of one hour to respond to 
a control setting adjustment. 
 
Defrost 
Your  Silver  King  refrigerator  is  an  automatic  defrost  unit  and  no  additional  plumbing  is  required.  Automatic  defrosting  is 
accomplished when frost buildup on the Evaporator Coil is cleared during Compressor off cycles. Defrost water is collected in a pan 
located  in  the compressor compartment  where  it  is  evaporated  into  the  room  air.  It  is  important  that  the unit  be  installed  level  to 
allow proper drainage of the defrost water. 
 
MAINTENANCE 
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 
the appliance. 
 
Cabinet Surfaces 
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of 
warm water and mild soap, rinsed and wiped dry with a soft cloth. A good stainless steel cleaner can also be used. Should a surface 
become stained, do not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the grain of the 
metal to avoid scratching the surface. Do not use chlorinated cleaners. Always rinse well and dry after cleaning. 
 
Condenser 
Periodically, accumulated dust must be removed from the condenser.   First, disconnect the unit from the power supply.  To clear 
the  dust,  vacuum  or  brush  the  condenser  at  the  bottom  rear  of  the  cabinet.    This  will  need  to  be  done  regularly  to  maintain  the 
compressor warranty! 
 
Drawer Gasket 
The Drawer Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure 
maximum cabinet performance and life. 