REPLACEMENT PARTS LIST – SKF27A-ED 115V 

 

ITEM NO.

PART DESCRIPTION

PART NO.

1

DRAWER ASSEMBLY COMPLETE

39959

2

DRAWER GASKET

10310-76

3
4
5
6
7

TEMPERATURE INDICATOR

22409

8

POWER CORD 115V

32199

DEFROST PROBE EVAPORATOR
TEMPERATURE PROBE

10

DEFROST HEATER EVAPORATOR

47076-SK

11

CAPILLARY TUBE EVAPORATOR

99035

12

EVAPORATOR COIL

38337

13

EVAPORATOR FAN MOTOR  115V/230V

39577

14

AIR CURTAIN ASSEMBLY

38353

15

   FILTER CONDENSER (OPTIONAL)

31221

CASTER KIT 2"

10314-100

CASTER KIT 3"

10314-63

17

KIT COMPRESSOR W/ ELECTRICALS 115V/60HZ

11700-2

18

KIT ELECTRICALS 115V (RELAY, OVERLOAD, RUN CAPACITIOR)

11701-2

19

GROMMET COMPRESSOR MOUNT

20481

20

WASHER COMPRESSOR MOUNT

22401

21

HAIRPIN CLIP COMPRESSOR MOUNT

98106

22

DRIER

22677

23

ELECTRONIC TEMPERATURE CONTROL 115V (PROGRMD)

45768

24

CONDENSATE PAN ASSEMBLY

38379

25

CONDENSER FAN MOTOR  115V/230V

39577

26

CONDENSER COIL

39259

27

REAR PANEL

45250

10451-04

FORM 45070 REV C

16

38822

9

KIT SLIDES 15.75" (FOR ONE DRAWER)

 

 

WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS. 

Summary of Contents for SKF27A-ED 115V

Page 1: ...cal Manual Replacement Parts List 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Freezer MODEL SKF27A ED 115V FORM NO 45071 REV D 07 2021 Specifications Subject to Change Without...

Page 2: ...t altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 75 pounds per drawer...

Page 3: ...ll the stop levers out on the Cabinet Drawer Tracks and lift up and pull the Drawer out To reinstall the Drawer line up the Drawer Tracks on the cabinet and the Drawer push the Drawer into the cabinet...

Page 4: ...re it is evaporated into the room air It is important that the unit be level so the condensate can drain properly MAINTENANCE Preventative maintenance is minimal although these few steps are very impo...

Page 5: ...4...

Page 6: ...5...

Page 7: ...CONDENSER OPTIONAL 31221 CASTER KIT 2 10314 100 CASTER KIT 3 10314 63 17 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 2 18 KIT ELECTRICALS 115V RELAY OVERLOAD RUN CAPACITIOR 11701 2 19 GROMMET COMPRE...

Page 8: ...7...

Page 9: ...pare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and te...

Page 10: ...ollowing the 1 year labor warranty period or other incidental or consequential costs including product and or economic loss This Equipment warranty is in lieu of all other warranties express or implie...

Page 11: ...ce include but are not limited to temperature control adjustments temperature indicator calibrations coil and filter cleaning or condensate drain cleaning A second service call for a related failure i...

Page 12: ...LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT OR RELATED TO OR CONNECTED IN ANY WAY WITH THE PRODUCT OR ITS USE Silver King 1600 Xenium Lane Pl...

Reviews: