CHARGING THE BATTERY
The TrolleyPak utilises a 12V DC sealed lead-acid
(SLA) battery which requires approximately 6-8
hours of charging from the supplied battery
charger to fully charge the battery.
Always charge the battery after use. Do not
leave the battery flat as it will damage the
battery.
The Selecta TrolleyPak is supplied with a battery
charger for SLA batteries with two available
charging voltages.
To correctly use this charger, always have the
charger set to 12V.
Ensure that the Troll
eyPak’s power on/off switch is set to off. To charge the battery, connect the
plug of the charger to the socket located at the rear of the sprayer as shown in the diagram above
and turn the power on the charger.
Once the battery has been charged or has been charging for over 8 hours, disconnect the charger.
Warning! Never leave the battery to charge unattended.
Warning! Do not charge damaged batteries.
Warning! Never charge the battery for periods of time longer than 8 hours. Over Charging the
battery can create an explosion and fire hazard.
CLEANING THE FILTER
To avoid chemical contamination, wear appropriate protective
equipment including gloves whenever maintenance is carried out.
Turn off the pump and depress the trigger on the spray lance to
dissipate any pressure, unscrew the cap on the filter housing in
order to remove the filter. Clean the filter with clean water and a
bristle-brush, do not use a wire brush or sharp object as this may
damage the mesh. Once the filter is clean, put it back into the filter
housing and replace the cap.
Maintenance