![siluj PAR36-RGB-12-1W-D-B User Manual Download Page 3](http://html.mh-extra.com/html/siluj/par36-rgb-12-1w-d-b/par36-rgb-12-1w-d-b_user-manual_1272286003.webp)
3
1
2
3
2
1
1 Ground
2 Signal(-)
3 Signal (+)
1 Ground
2 Signal(-)
3 Signal (+)
DMX - input
XLR mounting– socket:
DMX - output
XLR mounting– socket:
Only use a stereo shielded cable and 3-pin XLR– plugs and connector in order to connect the
controller with the fixture or one fixture with another.
Only use a stereo shielded cable and 3-pin XLR– plugs and connector in order to connect the
controller with the fixture or one fixture with another.
Occupation of the XLR– connector
If you are using controllers with this occupation. You can connect the DMX– output of the controller
directly with the DMX—input of the first fixture in the DMX chain. If you wish to connect DMX–
controller with other XLR– outputs, you need to use adapter cable
Building a serial DMX chain:
Connect the DMX– output of the first fixture in the DMX chain with the DMX– input of the next
fixture. Always connect one output with the input of the next fixture until all fixture are connected.
Caution: At the last fixture, the DMX– cable has to be terminated with the terminator. Solder a
200
Ω
resistor between Signal(-)Signal (+) into a 3 pin XLR plug and plug it in the DMX output
of the last fixture
If the projector shall be lowered from the ceiling or high joints, Professional trussing system have to
be used. the projector must never be fixed swinging freely in the room
Caution: Projector may cause sever injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do NOT install the projector
Before rigging make sure that the installation area can hold a minimum point load of ten times the
projector’s
DANGER OF FIRE!
When installing the device, make sure there is no highly inflammable material
( decoration articles , etc.) within a distance of min. 0.5m
Mount the projector with the mounting bracket to your trussing system using an appropriate clamps
For over head use, always install a safety rope that can hold at least 12 times the weight of the fix-
ture. You must only use safety ropes with quick links with screw cap. Pull the safety rope through
the hole in the mounting bracket and over the trussing system ar safe fixation spot. Insert the end in
the quick link and lighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already hold the strain of a crash or is defective must not be used again.
Adjust the desired inclination angle via mounting bracket and tighten the fixation screws.
Connect the fixture to the main with the power plug.
The occupation of the connection cable is as follows:
Cable
Pin
International
Brown Live L
Blue Neutral
N
Yellow/Green Earth
DANGER TO LIFE!
Before taking into operation for the first time, the installation
has to be approved by an expert!
DMX-512 connection / connection between fixture
The wires must not come into contact with each other, otherwise the
Fixture will not work at all, or will not work properly