Innovative Solar Solutions | 2917 State Hwy 7, Bainbridge, N.Y. 13733 | Ph: 800.786.0329 | www.SiliconSolar.com
7)
Turn the “ON/OFF” switch of the battery station to the “ON” position, then the “SYSTEM” status LED on the
battery shows green and the system is activated.
The “SYSTEM” status LED may show red with battery
outputting no power when the battery station operates for the first time, since the battery station
may lose its energy during the storage. It just needs to be charged for several hours in the
sunshine by facing the solar module towards the sun, then the “SYSTEM” status LED shows green
and the battery station is ready to work.
8)
The power output will be automatically cut off while the battery station is discharged to its low voltage limit,
and the “SYSTEM” status LED shows red in the meantime.
9)
The “SYSTEM” status LED stays in red before the battery is recharged to its starting voltage. After recharged
to its starting voltage, the battery shall continue to be charged for an extra hour with the “SYSTEM” status
LED flashing red-green twice every 10 seconds. Then the power output is resumed and the “SYSTEM” status
LED shows green again.
10)
Activate the output port 1 by pressing the corresponding “OUTPUT 1 ON/OFF” button on the top of the
battery station, the output 1 indicator shows green and the pump starts to work. To stop the pump, just
disable the output 1 by pressing the “OUTPUT 1 ON/OFF” button again.
11)
The “TIMER ON/OFF” button switches the running mode of the pump hooked up to output 1 between
"intermittent mode" and "continuous mode". In the “intermittent mode” (i.e., “TIMER ON”), a build-in timer is
enabled to run the pump for 10 minutes per hour to save the energy, and it is especially useful in winter or
on cloudy days. In the "continuous” mode, the build-in timer is disabled and the pump shall run continuously
until the battery exhausted.
12)
The “CHARGING” yellow LED indicator lightens when the battery is being charged, otherwise the LED indicator
shuts off.
13)
If you want the pump to have longer operating time in the evening, then turn the battery ”ON/OFF” switch to
“OFF” position during the day time and turn it to “ON” position whenever you need.
Note: * The battery will always be charged in the
sunlight no matter whether the battery “ON/OFF”
switch has been turned to “ON” or “OFF”! And the
system automatically cuts off the charging current
when the battery is charged to its high voltage limit
(fully charged).
4.
CAUTIONS
1)
Any altering of the product itself or changing of the components voids warranty.
2)
Do not connect the pump to any AC voltage power directly; it’s ONLY for DC
voltage power.
3)
Operate the pump in water only (never above 40
℃
), especially keep it away
from flammable liquids.
4)
All the connectors are protected against reverse polarity as shown in the right
figure. Don’t insert the plug with reverse polarity by using unnecessary force.
5)
The pump is dry run protected. The pump will automatically stop when there is no enough water.
5.
CLEANING AND MAINTENANCE