1.  Handling Recommendations

To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective
plastics. To prevent damage to the devices and/or the host PC, please take into consideration the following
recommendations when using the ToolStick:

Never connect or disconnect a daughter card to or from the ToolStick Base Adapter while the Base Adapter is 
connected to a PC.

Always connect and disconnect the ToolStick from the PC by holding the large plastic connector.

Figure 1. Proper Insertion

Avoid directly touching any of the other components.

Figure 2. Improper Insertion

Manipulate mechanical devices on the daughter cards, such as potentiometers, with care to prevent the base 
adapter or daughter card from accidentally dislodging from their socket.

Downloaded from

Arrow.com.

Summary of Contents for ToolStick Debug Adapter

Page 1: ...ing recommendations when using the ToolStick Never connect or disconnect a daughter card to or from the ToolStick Base Adapter while the Base Adapter is connected to a PC Always connect and disconnect the ToolStick from the PC by holding the large plastic connector Figure 1 Proper Insertion Avoid directly touching any of the other components Figure 2 Improper Insertion Manipulate mechanical device...

Page 2: ... adapter from the USB connection to the PC The ToolStick Debug Adapter is capable of providing power to a circuit board via pin 10 of the DEBUG connector See the respective kit user s guide for instructions on powering a target board from this source Please note that not all of the Silicon Laboratories MCU development boards support being powered from the debug adapter Table 1 shows the pin defini...

Page 3: ...lStick Base Adapter 2 Connect the 10 pin ribbon cable from the ToolStick Debug Adapter to the Target Board debug header 3 Connect one end of the USB cable to the USB connector on the ToolStick Debug Adapter 4 Connect the other end of the USB cable to a USB port on the PC that will run the Silicon Laboratories IDE 5 Connect the AC DC power adapter to the power jack on the target board or configure ...

Page 4: ...Options in the IDE menu 3 Select USB Debug Adapter in the Serial Adapter section 4 If more than one adapter is connected choose the appropriate serial number from the drop down list 5 Next the correct Debug Interface must be selected Check the Debug Interface corresponding to the Silicon Laboratories device on the target board 6 Once all the selections are made click the OK button to close the win...

Page 5: ...ToolStick Debug Adapter Rev 0 1 5 6 ToolStick Debug Adaper Schematic Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Page 6: ...t personal injury or death Silicon Laboratories products are generally not intended for military applications Silicon Laboratories products shall under no circumstances be used in weapons of mass destruction including but not limited to nuclear biological or chemical weapons or missiles capable of delivering such weapons Trademark Information Silicon Laboratories Inc Silicon Laboratories Silicon L...