6.5 Applied Emission Limits for the 2.4 GHz Band
The above ETSI limits are applied both for conducted and radiated measurements.
The FCC restricted band limits are radiated limits only. In addition, Silicon Labs applies the same restrictions to the conducted spec-
trum. By doing so, compliance with the radiated limits can be estimated based on the conducted measurement, by assuming the use of
an antenna with 0 dB gain at the fundamental and the harmonic frequencies.
The overall applied limits are shown in the table below.
Table 6.2. Applied Limits for Spurious Emissions for the 2.4 GHz Band
Harmonic
Frequency
Limit
2nd
4800~4967 MHz
-37.6 dBm
3rd
7200~7450.5 MHz
-37.6 dBm
4th
9600~9934 MHz
-30 dBm
5th
12000~12417.5 MHz
-37.6 dBm
BRD4174B Reference Manual
EMC Compliance
silabs.com
| Building a more connected world.
Rev. 1.00 | 13