Powering Server On and Off
007-4653-001
23
Powering On D-brick2
Before powering on the D-brick2, confirm that the following is true:
•
Drives are seated in the correct bays and blank plates are fitted in any empty bays.
•
Ambient temperature is within the specified range of 10
°
C to 40
°
C (50
°
F to 104
°
F).
•
The rack power distribution unit (PDU) and power distribution strip (PDS) are on.
To power on the D-brick2, follow these steps:
1.
Connect an AC power cord to each PSU/cooling module.
2. Connect the AC power cords to the PDS.
3. Turn the power switch on each PSU/cooling module to the “on” position (
1
= on,
0
= off). The location of the power switch on the D-brick2 PSU/cooling module is
shown in Figure 1-15.
Figure 1-15
D-brick2 PSU/cooling Module Power Switch
The green “PSU good” LED illuminates. Also, the “power on” LED on the ESI/ops panel
of each module turns green when AC power is present.
If the “power on” LED on the ESI/ops panel does not illuminate, or if the amber
“system/ESI fault” LED illuminates, verify that you followed all steps. For
troubleshooting tips, see the
SGI Total Performance 9100 (2Gb TP9100) Storage System
User’s Guide
or contact your service provider.
Power on/off switch
(I = on)
AC power input
Summary of Contents for Origin 3900
Page 1: ...SGI Origin 3900 Server User s Guide 007 4653 001 ...
Page 3: ...007 4653 001 iii Record of Revision Version Description 001 October 2003 Original Release ...
Page 4: ......
Page 12: ......
Page 18: ......
Page 62: ......
Page 65: ...Product Description 007 4653 001 39 Figure 2 1 512 processor Origin 3900 Server ...
Page 76: ......
Page 104: ......
Page 120: ......
Page 172: ......
Page 198: ......
Page 208: ......
Page 254: ......
Page 274: ......
Page 292: ......