background image

Infinity View| Temple Shortening - Glued

TECHNICAL INFORMATION INFINITY VIEW

13

6. Gently remove 

remaining glue.

7. Cut plastic temple end to required 

length with sharp blade in the 
original angle.

Summary of Contents for Infinity View 1600

Page 1: ...Infinity View Technical Instructions Models 1600 2937 2938 2939 V Bevel Edging...

Page 2: ...g our exclusive Panorama lens designs Silhouette Vision Sensation lenses perfectly match the curve of every Silhouette frame This results in a 100 Silhouette eyewear solution that offers the wearer ex...

Page 3: ...Mount temples on frame front using BLS 58 sleeve and Silhouette mounting plier with turquoise or blue tip Infinity View Temple Mounting...

Page 4: ...er other base curves will work Lenses with base curves flatter than 5 0 should have V bevel cut to match 5 0 base curve Recommended lenses are High Index 1 6 1 67 Polycarbonate and Trivex OMA shape fi...

Page 5: ...TECHNICAL INFORMATION INFINITY VIEW 5 Cold insert lenses in all Infinity View frames Do not heat the frame under any circumstance Lenses that are too large will need to be resized Always insert lenses...

Page 6: ...m TECHNICAL INFORMATION INFINITY VIEW 6 1 Insert the lens from the rear starting with the nasal corner 2 Continue inserting the lens along the top to the temporal corner 3 Continue around the lens cir...

Page 7: ...Infinity View Lens Removal TECHNICAL INFORMATION INFINITY VIEW 7 1 At the bottom of the frame partially push frame back and separate the frame from the lens 2 Push lens out of frame toward the front...

Page 8: ...lination Infinity View 1 Open the temple 2 Support the temple mount with the Silhouette mounting pliers 3 Incline the temple at the endpiece in the desired direction TECHNICAL INFORMATION INFINITY VIE...

Page 9: ...iew Temple Opening Increase TECHNICAL INFORMATION INFINITY VIEW 9 1 Open the temple 2 Support the temple mounting with Silhouette mounting pliers 3 Press the temple out at the endpiece with thumb or i...

Page 10: ...ew Temple Opening Decrease TECHNICAL INFORMATION INFINITY VIEW 10 1 Open the temple 2 Support the temple mounting with Silhouette mounting pliers 3 Press the temple in at the endpiece with thumb or in...

Page 11: ...Bend Adjustment TECHNICAL INFORMATION INFINITY VIEW 11 1 Adjust the temple to the ear shape with large curves 2 Temple can be heated to aid adjustment 3 During temple end adjusting do not put pressur...

Page 12: ...MATION INFINITY VIEW 12 1 Straighten the end of the temple 2 Break the adhesive bond by squeezing with with double jaw padded pliers 3 Carefully pull off the temple end 4 Shorten titanium wire with me...

Page 13: ...Infinity View Temple Shortening Glued TECHNICAL INFORMATION INFINITY VIEW 13 6 Gently remove remaining glue 7 Cut plastic temple end to required length with sharp blade in the original angle...

Page 14: ...ening Glued TECHNICAL INFORMATION INFINITY VIEW 14 8 Reinstall temple cover 9 Apply a small amount of glue on the inside of the titanium wire as shown 10 Slide the temple cover fully onto the titanium...

Page 15: ...mple Removal TECHNICAL INFORMATION INFINITY VIEW 15 1 Close the temple and hold the lens mount with your thumb and index finger 2 Using other hand pull the temple off from the endpiece in direction sh...

Page 16: ...l TECHNICAL INFORMATION INFINITY VIEW 16 1 Support the frame front as shown 2 With the temple in the closed position align the temple to the hinge elements on the endpiece with the temple slots 3 Pres...

Page 17: ...Infinity View Teflon Lubricant After cleaning the frame in an ultrasonic bath relubricate the hinge with Teflon TECHNICAL INFORMATION INFINITY VIEW 17...

Page 18: ...Infinity View Cleaning in an ultrasonic bath or with ethanol is possible Avoid high temperatures such as the dashboard in the car or the sauna Always use the supplied case for storage TECHNICAL INFORM...