background image

14   

   

The pink Up / Down arrows are used to increase or decrease the intensity. Modifying treatment 
parameters will affect only the wave power. 

The wave’s total duration will not change.

  

 
 
 

T  =>  Time  /  seconds  represents  the  duration  of  Thermolysis  / 
Electrolysis wave. 

UE => Total RF energy. 

MAX => is the maximal value that RF energy wave will reach. 

 

UE => Total DC energy of Electrolysis wave. 

MAX=> The maximum value that DC current will reach. 

 

When  selection  « 

By  Hair  Type

 »  is  used,  wave  duration  can  be  adjusted  by  pressing  pink 

arrows Left / Right into the “Time” square. The graph displays wave duration accordingly. 

  

 

 

 

 

 

Summary of Contents for EVOLUTION 5HD

Page 1: ......

Page 2: ...tion 5HD treatment release form 24 10 Client post care instructions 25 11 Accessories for with Evolution 5HD 26 12 Important 27 13 WARRANTY 27 14 SPECIFICATIONS 28 All rights reserved No part of this...

Page 3: ...anent results faster Vector Modulation TM is more accurate and stable than any other existing technology This technology uses a two millisecond segment current the fastest on the market to maximize th...

Page 4: ...anently Permit rapid destruction of all hair growing cells Achieves quicker permanency Is effective on all hair types fine medium heavy light or dark Eliminates ingrown hairs Does not damage the surro...

Page 5: ...ancy Prescription blood thinning drugs anti coagulants such as Warfarin or Coumadin Viral hepatitis HIV Cancer Keloid scars Rosacea during active phase or with severe acne Infectious acne Herpes simpl...

Page 6: ...ve back cover Refer servicing to qualified service personnel Rear side 1 Power outlet 2 ON OFF switch 3 Fuse box 4 Pedal outlet big black outlet 5 Soothing roller electrode red outlet 6 Contact electr...

Page 7: ...6 Front side 8 Probe Holder Connection Right side 9 Screen pen and probe holder supports 10 Standby button...

Page 8: ...lite to be plugged into 7 Satellite outlet silver outlet on the rear unit s side Onto the Front panel Cable for Probe holder thicker end to be connected into 8 Probe Holder Connection on the front uni...

Page 9: ...e probe holder or the tip of the needle in contact with the screen surface The probe carries high voltage and will damage the screen Turning the unit ON 1 To turn the unit on use the power switch loca...

Page 10: ...ace the unit in STANDBY mode 1 by pressing the blue standby button located on the right side of the unit or 2 by holding the standby button for few seconds which brings up the menu on the screen then...

Page 11: ...Soothing phase program Ana Cata Refer to section Soothing Phase into the 04 Treatment Screen Chapter for treatment details The TOOL key on the bottom left of the screen is a configuration key that ena...

Page 12: ...be applied You are now ready to work Turning the unit OFF There are two ways to turn the unit OFF 1 by using the power button located at the back or 2 by holding the standby button for few seconds wh...

Page 13: ...ams designed for its own sensitivity and degree of difficulty A fine hair on the chin does not respond the same way as a fine hair on the upper lip These programs insure maximum comfort for the client...

Page 14: ...e screen displays all treatment parameters NOTE Two dials display parameters for Thermolysis and Electrolysis DC current ONLY in following modes Depilation Face Chin Very coarse hair Depilation Face S...

Page 15: ...ds represents the duration of Thermolysis Electrolysis wave UE Total RF energy MAX is the maximal value that RF energy wave will reach UE Total DC energy of Electrolysis wave MAX The maximum value tha...

Page 16: ...sor is Off black color the current must be activated with the pedal Deformed key is used to provide extra bursts of energy when working with difficult or distorted hair follicles Blend key will only a...

Page 17: ...trodes when switching between Cata and Ana Default treatment time is 3 minutes DC current intensity can be increased or decreased by 1 10th of a mA milliamp increment Pressing the On key will start th...

Page 18: ...bactericidal wipes to disinfect roller Recommended intensity settings for Cata mode For Face 0 35 mA to 1 00 mA For Body 1 00 mA to 2 00 mA Treatment should be comfortable and soothing Client should...

Page 19: ...ode is selected by using the Treatment Duration bar True Time Mode To use the timer as a countdown timer select the desired treatment time using the up or down arrow keys on the timer panel It will ch...

Page 20: ...ays be accurately inserted into the follicle at the moment of current activation Note It is not recommended to work with the Sensor delay mode when work areas present difficult insertions or tight fol...

Page 21: ...ithin range In this example engwifi is available but is a secure network this is noticeable by the lock next to the signal icon When the unit is connected to the internet the word CONNECTED will appea...

Page 22: ...client to a physician Do not treat moles In case of health problems or medical conditions or any doubt refer client to a physician or ask for a written authorization from the client s physician Before...

Page 23: ...The optimum stage for treatment has passed The growth process has reversed itself and the hair is preparing to shed The moisture water and salt content is diminishing Follicle destruction is almost i...

Page 24: ...d Use probes that are Disposable One piece Supplies needed for treatment Pre depilation cleanser such as Sensibilis Pre depilation lotion Gloves some clients are allergic to latex or vinyl Surgical ma...

Page 25: ...s might include mild redness extreme redness local swelling and stinging Most side effects are temporary and generally subside within one week to 21 days __________ initials I have been advised not to...

Page 26: ...fingers and facial cleanser Do not use face cloth facial brush or sponges If you wish to wear makeup over treated area apply foundation very gently using clean fingers Avoid sponges as they may harbo...

Page 27: ...ome Gift F2 Non Insulated 1 piece needles 30 1 F3 Non Insulated 1piece needles 30 1 Promotional Material Instruction Manual paper version available to be ordered Professional Brochure 1 Evolution 5 HD...

Page 28: ...PONSIBLE FOR DAMAGE OR ACCIDENTS DUE TO THE INCORRECT USE OF THE UNIT 13 Warranty The Evolution 5HD unit is warranted to be free from any manufacturing or assembly defects for two 2 years from the dat...

Page 29: ...ocessor controlled SILHOUET TONE RESERVES THE RIGHT TO CHANGE THE SPECIFICATIONS OF THE EVOLUTION 5HD UNIT WITHOUT NOTICE All rights reserved No part of this work covered by the copyright hereon may b...

Page 30: ...Silhouet Tone 2013 09 18...

Reviews: