SILENTRON 4090 Sil Bus Instructions And Warnings For Installation And Use Download Page 4

 

Declaration of CE conformity: 

Nice s.p.a. declares under its sole responsibility that the products described in this manual comply with the requirements set 

out by the Directives LVD 2014/35/EU - EMC 2014/30/EU. The adjourned declaration is available in our sit

www.silentron.it/dichiarazioni-ce/

 

 

Warnings: 

the equipment described here must be installed and commissioned by specialized technicians, in compliance with the regulations in force. 

 

Operation: 

this equipment is expressly designed to allow the communication between WiFi devices and Sil-Bus alarm control units. Caution! The FW 

version of the control unit/Touch must be 3790L/3720L or later: earlier versions must be updated first. 

 

Self-protection: 

the equipment has no anti-opening or anti-removal kit since any tampering does not constitute a danger to the safety of the system. Any 

impossibility to check/control the control unit via intranet and/or internet is replaced by other means of control in the unit. 

 

Installation instructions: 

a)

 

Open the box and secure it in a practical spot for the connection of the bus cable to the system 

b)

 

Make sure that the Bus line in not powered and connect the terminal board of the equipment to the 4 wires of the Bus line as shown. The non-insulated 

part of the conductors must be fully inside the terminals, to prevent short-circuits. It is possible to use wires measuring 0.15 in diameter for short distances 
(<2m) between the Bus line and the equipment. 
c)

 

Connect the supply: when the Bridge is not paired L1 flashes red, while L2 flashes green. 

d)

 

Carry out the learning procedure described in the manual of the Sil-Bus control unit and proceed with the configuration 

 

Programming as Access Point or Client and the consequent operation of the equipment are described in the manual of the control unit, since they are 
strictly connected with the operation of the control unit itself. 

 

Updating the Bridge: 

the equipment can be updated, if necessary, 

using a PC in local network with the Bridge itself. In Chrome, enter 
the IP address of the Bridge that can be read on the touch keyboard 
of the control unit (see the control unit instructions), then launch the 
latest software update (previously downloaded onto the PC). 

 

Resetting the Bridge parameters: 

press P1 for 10 seconds until all 

LEDs light up orange. The Bridge then restarts and returns to 
condition c). 

 

Bridge total reset: 

only if the update has been unsuccessful, the 

factory software can be reset. Temporarily disconnect the positive of 
the Bridge and reconnect it keeping button P1 pressed for 10 
seconds: LED 2 flashes red until the equipment restarts, returning to 
situation c). 

 

LED display: 

 

L1 

WiFi connection 

Green = Connected to the router or APP mode 

Flashing red = No connection 

L2 

Flashing green: live Bridge 

L3 

Flashing orange: shows the BUS connection 

 

Technical characteristics: 

environmental category 2 - internal 

supply: Bus line rated 12V DC - absorption: 30mA 
box dimensions: 121 x 84.7 x 58 mm 
storage and use temperature: -10+40°C 