background image

Silent Gliss Ltd. 

 0939 Multi room Handheld Controller

: User guide Page 2 of 7

 

If the blinds are of the Venetian type the motor control module may have been set with ‘momentary’ action.  In momentary mode the open/close keys will 
allow short presses to change the louvre tilt and releasing the key after a short time will stop the change in tilt.  To fully open/close the blind keep the 
appropriate key held until the control module ‘latches’ (default setting for this is 1.5 seconds) and then release, the blind will now travel to fully 
opened/closed without any further input. 

To access individual blind control press the up/down keys to scroll between blinds, or press ‘All’ to return to the Overall control screen.   
To change rooms press the ‘Room’ key (to access Screen C2) and then use the up/down keys to scroll between rooms, use the Enter key to select. 

Grouped Rooms

 – It may be desirable to have rooms that have a logical association ‘grouped’ with the shortcut key giving quick navigation between these 

rooms.  An example would be an open plan kitchen/lounge area where the blinds in each room have been set as different rooms to give separate room control 
when using ‘Overall Open/Close’ but the user may well want to access both rooms quickly.  Once a room in a group is selected the shortcut key will scroll 
through all the rooms in the group, if there are only two rooms this action will appear as a ‘toggle’.    

Configuring the 0939 manually 

– Before

 

configuring the 0939 the Silent Gliss system to be controlled needs to be programmed, once this is complete the 

0939 can be set-up to control the desired rooms with any required channel and scene information.     

Entering setup mode – 

From the Room select screen (C2) press the left right and shortcut keys simultaneously. You cannot Enter set up from all screens.

 

To exit setup mode press quit twice   

The following notes should be read whilst referring to the Main Setup Menus pages of this manual.  The notes assume that the handset is in setup 
mode (see above). 

To assign House Address and Enable Rooms the user must know the numbers assigned to the receivers to be controlled.  This will be available either 
from the installer or by examining the Address Switch settings on a Silent Gliss wallplate and referring to the wallplate manual. 

Setting the House Address 

– To Enter the House address use the down key to navigate to Screen D2 (Choose House), press Enter to display the current 

house (Screen D21) and then scroll up or down to the desired house number and press Enter.  

 

Note: The following functions are the most commonly accessed functions of the handset 

Summary of Contents for 0939

Page 1: ...way refer to the software Help file For clarity this manual refers to blind control only although all aspects are equally applicable to curtain control Switch On To turn the 0939 on press any key A Sp...

Page 2: ...may well want to access both rooms quickly Once a room in a group is selected the shortcut key will scroll through all the rooms in the group if there are only two rooms this action will appear as a t...

Page 3: ...p down keys to select the desired channel and press Enter to access the name Use the up down and right left keys to edit the name once edited press Enter and then save Set Default The default screen a...

Page 4: ...wn key to highlight Disabled and use the Enter key to toggle between Disabled Enabled Use the down key to highlight the room and use the right left keys to scroll through the active rooms until the fi...

Page 5: ...pen Close Blinds Room Select Screen BASIC OPERATION FOR CURTAIN BLIND CONTROL Press or to change room Start Up Splash screen SWITCH ON C1 C2 Press to close blinds Press to open blinds Press Enter to s...

Page 6: ...ate with your Silent Gliss system Group Commands Useful for quick selection of different rooms using Shortcut key Can be used for quick navigation between eg lighting and blind control as these should...

Page 7: ...or for Lighting control ROOM SETUP MENUS Enter Enabled Room 004 Room A Save En Quit Enabled Room 004 Room A Save En Quit Delete Room 004 Room A Save En Quit Enabled Room 004 Room A Save En Quit Enter...