Any questions? Call us on 01246 450789
TM
Alert
Silent
The Monitor can be configured to poll every 5 minutes where radio integrity checking is required.
Advanced Settings
Range Test mode
To perform a range test mode switch key
16 to the right.
On the receiver, switch keys 5, A & B on
to the left.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Pager
A
B
5
4
3
2
1
ON /OFF
O
N
SignWave
The monitor will send a signal every 5 seconds. The
receiver will display the signal strength by lighting a
symbol on the receiver.
Walk around the area you need to cover to ensure total
site coverage. The battery key represents the lowest
point at which the signal strength is reliable.
100%
Signal Strength
Quick start guide UM3A-2212-EU-PSU
Smoke / Carbon Monoxide Monitor with inline PSU
Radio Interlace
If two or more monitors in close
proximity are configured to
polling mode a transmission
delay on one monitor is required.
Switch key 8 to the right on
one
of the monitors.
When the unit is triggered there
will now be a three second delay
before it transmits.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
(only required if 2 or more Universal Monitors are used)
Polling signal
Switch key 9 to the right.
The unit will now send a
polling signal every
5 minutes.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Configure the Pager or SignWave as shown
(switch
keys 5 & A
on to the left).
The Smoke symbol will flash red every seven seconds
to show the receiver is monitoring for radio integrity.
If the Pager or SignWave doesn't receive a signal within
5 minutes it will flash all lights and alarm 5 times.
This will continue every 5 minutes until a valid polling
signal is received
.
Pager
A
B
5
4
3
2
1
ON /OFF
O
N
SignWave
Receiver configuration for polling (radio integrity check)
PLEASE NOTE
.
THIS PRODUCT
DOES NOT
COMPLY WITH BS5839-1 2002. HOWEVER, THE FIRE SAFE INTERFACE PANEL, ALSO
AVAILABLE FROM CLOFIELD Ltd (PART NUMBER FSTX-2225-EU) DOES
.