The monitor can be coded to light any one of the event symbols on the Pager or SignWave.
The diagram below shows the relevant key settings.
Event Setting
Changing the system channel code
NOTE:
In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other SA3000 systems using up to a maximum of 16 channels.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
Voltage triggering
A voltage applied across
terminals 1 & 2 will also
trigger the unit. Both AC and
DC voltages from 5 - 30 Volts
will activate the unit.
6.
WARNING
DO NOT
apply mains power or any voltage in
excess of 30 Volts as damage will result.
Only suitably qualified persons should attempt to
link this unit into systems or equipment other
than a low voltage door chime
4.
The input terminals can be used to
connect to doorbells, door entry
phones, fire, burglar & car alarms.
UM3A-2212-EU-PIR-MKX
Universal Monitor 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
Short Circuit triggering
A short applied across the
top and bottom terminal will
trigger the unit.
5.
7.
8.
Common (negative)
to terminal one
Wiring example
When wiring across a coil
or similar, use the
voltage input.
When wiring parallel across
a bell push use the short
circuit input.
Make sure the common
(negative) wire on the bell push
is connected to the bottom
terminal to avoid
false triggering.
TM
S
i
lent
Alert
Advanced settings UM3A-2212-EU-MIC
Universal Monitor with External Microphone
Any questions? Call us on
+353 (0)1 247 9007