The Care Call System comprises a SignWave Receiver (with Base) and at least one transmitter option. Clofield Ltd., Chesterfield, 
England. Help Line 0800-387-397, Txt 01246-572141,  Fax 01246-450789 e-mail 

[email protected]

 

                      

 
Event Display 

 

 

8.  It is possible to show a total of 12 indications on the SignWave event display. Event 1 to 6 will be indicated with 

a single light on the relevant key. The Battery Light (+6) plus a numbered key indicate events 7 to 12. Event 7 is 
represented by the Battery Key (+6) and Key 1, 8 by Battery Key(+6) plus Key 2 and so on. 

 
Control Switch settings 

 
 

9.  Control switches 1-4 are for system coding (to switch ON 

– using the edge of the front cover move the switch to 

the left away from the number adjacent to each switch). The switch settings need to correspond with the settings 
of each transmitter option. 4 Control switches can be used to create a total of 16 different system channels and 
should only be used where another system is being used in a dwelling close by. 

10.  Control switch 5 increases the operating range of the unit and should only be used where the operating range is 

insufficient for a particularly large dwelling.  

11.  Control Switches A & B are not used and should be left in the OFF position. 

 

Volume Control 

 

12.  The volume of the integral sounder can be altered using the volume control. Clockwise movement will increase 

the volume whilst anticlockwise movement will reduce the volume.  

 

Low Battery 

 

13.  When fully charged the integral battery should last approximately 4 days, although the unit should be placed on 

the base unit on a bedside table each night to charge and provide night time cover. If the battery becomes low 
the unit will buzz, the strobe will flash and the Battery Symbol will flash orange, four times. This sequence  will 
repeat once every 15 minutes until the unit is recharged on the Base Unit. 

 

Strobe & Sounder Options

 

 

14.  To alter the strobe and sounder options press and hold the Cancel Button. After 4 seconds the sounder will buzz 

once,  the  strobe  will  flash  once  and  each  key  will  light  from  bottom  to  top  in  sequence.  Continue  holding  the 
button and a sequence of strobe flashes and sounds in combination with a light on the Event Display as shown 
below. Release the Cancel Button immediately after the desired combination occurs. If the desired combination 
is missed continue holding the button until the sequence is repeated. 

 
Key 1 +  Normal frequency Buzz =  Normal frequency Sound + Strobe (default setting) 
 
Key 2 +  High frequency Buzz =  High frequency Sound + Strobe 
 
Key 3 + Normal frequency Buzz =  Normal frequency Sound 

– No Strobe 

 
Key 4 + High frequency Buzz =  High frequency Sound 

– No Strobe 

 
Key 5 = Symbol only - No Sound 

– No Strobe 

 
 
 

 

DO NOT IMMERSE THE ALARM IN WATER OR ANY OTHER LIQUID. DO NOT SUBJECT THE UNIT TO 
EXCESSIVE MECHANICAL SHOCK. 