SIL GTIS Power Systems Villager III User Instructions Download Page 7

Precautions

Water

The Villager III is not waterproof. Do not leave it 

outdoors in the rain or immerse it in water. If water gets 
inside the case, turn off the toggle switch and allow the 

Villager III to dry thoroughly before using it.

Heat

Cooler temperatures will improve the lifetime of the 

batteries and electronics. Whenever possible, avoid leaving 

the Villager III in hot locations or in direct sunlight.

Battery Failure

The Villager III contains three separate LiFePO4 smart 

battery packs. When one of the batteries gets old and fails, 

its internal electronics board will prevent it from charging or 
discharging, resulting in sharply reduced capacity for the 

Villager III. When one fails, all three batteries should be 
replaced at the same time.  

Do not attempt to bypass the 

circuit board inside the battery and force charge a failed 
battery

 because it can catch on fire!

Contact 

[email protected]

 for replacement 

batteries or parts.

Summary of Contents for GTIS Power Systems Villager III

Page 1: ...Villager III User Instructions GTIS Power Systems power_systems sil org...

Page 2: ...can also provide 15 V to 24 V regulated DC for laptops BGANs etc The Villager III can store 216 watthours of energy Your repeating daily loads should be about 100 watthours or less which is sufficien...

Page 3: ...Power Systems can supply you with the correct connector NEMA 6 15P for the solar panel Proper polarity for the solar panel connector is shown below the T slot is positive the flat slot is negative the...

Page 4: ...two 12 volt output sockets D that may be used to charge devices You may plug in any DC adapter or inverter designed for automotive use however do not exceed 145 watts of load The voltmeter C will sho...

Page 5: ...rcuits in the system If the overload is not removed quickly the Villager III will try to restart every 15 minutes You can speed this up by turning off the main on off switch and turning it back on aft...

Page 6: ...al batteries individually before using it Have a technician remove the batteries and charge each one individually on a test bench at 2 amperes until the battery voltage reaches 14 2 V A flameproof con...

Page 7: ...in hot locations or in direct sunlight Battery Failure The Villager III contains three separate LiFePO4 smart battery packs When one of the batteries gets old and fails its internal electronics board...

Page 8: ...display meters may read as much as 0 2 volts lower or higher than actual value Charged Voltage While Charging Voltage After Discharging and Resting 10 Min 90 to 100 13 7 V 13 3 V About 75 13 5 V 13 2...

Reviews: