Quick Start Guide
MSAC506 · Date
08.01.2019 · Art.
No.
89494 · Mod.
status
284/18
SIKO GmbH
Weihermattenweg 2
79256 Buchenbach
www.siko-global.com
Phone
: + 49 7661 394-0
Fax
: + 49 7661 394-388
Service
MSAC506
Magnetic sensor
For detailed documentation please refer under
http://www.siko-global.com/p/msac506
General information
Prior to installation, including in hazard areas, read the Installation Instruc-
tion (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
•
Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
•
It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation Instruction.
•
It is the responsibility of the customer to ensure that the magnetic sensor is
correctly connected and configured.
•
Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
Mounting of the magnetic sensor
The sensor collects the absolute angle information of the coded MRAC506 mag-
netic ring.
Notice!
The tolerance and gap measures must be observed over the whole measuring
length.
Positive rotation direction
Admissible deviation
middle of ring/sensor
0.
1 ... 1 mm
<0.5°
±1.5
Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the sensor or the connection lines!
•
Use of screened connection cable with trunk cable in pairs.
•
When mounting the system keep a maximum possible distance from lines
loaded with interference. Use screening shields or metallized housings.
Connection
Pin
Signal
Description
1
Sin
Positive analog output
2
GND
Sensor earth connection
3
/Sin
Inverted analog output
4
/Cos
Inverted analog output
5
T+
SSI cycle input +
6
Cos
Positive analog output
7
D+
SSI data + or DÜA in service mode
8
T-
SSI cycle input -
9
+UB
Operating voltage sensor
10
D-
SSI data - or DÜB in service mode
11
Config
Configuration input
12
nc
Not used
Technical data
Electrical data
Additional information
Operating voltage
4.5 ... 30 V DC
reverse polarity protected
viewing side =plug-in side
plug pin
8
9
10 2 3 4
11
5
6
7
12
1