Siko MSAC506 Quick Start Manual Download Page 2

Quick Start Guide

MSAC506 · Date 

08.01.2019 · Art. 

No. 

89494 · Mod. 

status 

284/18

SIKO GmbH

Weihermattenweg 2
79256 Buchenbach

www.siko-global.com

Phone

: + 49 7661 394-0

Fax

: + 49 7661 394-388

Service

: [email protected]

MSAC506

Magnetic sensor

For detailed documentation please refer under  

http://www.siko-global.com/p/msac506

General information

Prior to installation, including in hazard areas, read the Installation Instruc-
tion (download from the internet). It contains the safety instructions, hints 
and technical data to be observed during installation. Subject to change with-
out notice.

 Caution

In order to ensure reliable functioning of this product, take care to transport, 
store, position and mount it appropriately. Exercise care when you operate and 
maintain the device. Only properly qualified personnel is authorized to install 
and operate this product.

Safety information

It is important for safety reasons that you read and understand the below 
instructions before you install the system:

• 

Installation, connection, commissioning and maintenance shall be done by 
properly qualified personnel.

• 

It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of 
the Installation Instruction.

• 

It is the responsibility of the customer to ensure that the magnetic sensor is 
correctly connected and configured.

• 

Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.

Mounting of the magnetic sensor

The sensor collects the absolute angle information of the coded MRAC506 mag-
netic ring.

 Notice!

The tolerance and gap measures must be observed over the whole measuring 
length.

  

  

Positive rotation direction

Admissible deviation 

middle of ring/sensor

0.

1 ... 1 mm

<0.5°

±1.5

Electrical Installation

The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the sensor or the connection lines!

• 

Use of screened connection cable with trunk cable in pairs.

• 

When mounting the system keep a maximum possible distance from lines 
loaded with interference. Use screening shields or metallized housings.

Connection

Pin

Signal

Description

1

Sin

Positive analog output

2

GND

Sensor earth connection

3

/Sin

Inverted analog output

4

/Cos

Inverted analog output

5

T+

SSI cycle input +

6

Cos

Positive analog output

7

D+

SSI data + or DÜA in service mode

8

T-

SSI cycle input -

9

+UB

Operating voltage sensor

10

D-

SSI data - or DÜB in service mode

11

Config

Configuration input

12

nc

Not used

Technical data

Electrical data

Additional information

Operating voltage

4.5 ... 30 V DC

reverse polarity protected

viewing side =plug-in side 

plug pin

8

9

10 2 3 4

11

5

6

7

12

1