MS100/1
Identification English
MS100/1 · Date
27.04.2018 · Art.
No.
82106 · Mod.
status
118/18
15
External magnetic fields
Failures and data loss occur if strong magnetic fields influence the internal
measuring system.
`
Protect the magnetic sensor from impact by external magnets.
3 Identification
Please check the particular type of unit and type number from the identifi-
cation plate. Type number and the corresponding version are indicated in
the delivery documentation.
e. g.
MS100/1
-
0023
variant number
type of unit
The magnetic tape is identifiable by a consecutive imprint.
e. g.
MBxxxx GEK WT RP NNNNNN
batch number
reference point
material carrier tape
accuracy
MB type
4 Installation
4.1 Mechanical mounting
Magnetic sensor failure
`
When mounting pay attention to the IP type of protection (see chap-
ter
.
`
Do not open the sensor yourself.
`
Avoid blows to the unit.
`
Make any changes to the unit.
`
The cable must be provided with strain relief. If necessary use drag
chain or protective sleeve.
Loss of measured values
`
The tolerances and distance dimensions must be observed over the
whole measurement length.
Exemplary sensor figures are valid for all sensor types unless described
separately.
CAUTION
CAUTION
NOTICE
NOTICE
Summary of Contents for MS100/1
Page 22: ...MS100 1 22 ...
Page 23: ...MS100 1 23 ...