MA508

Electronic display

For detailed documentation please refer under  

http://www.siko-global.com/en-de/service-downloads/download-products

General information

Prior to installation, including in hazard areas, read the Installation instrunc-
tion (download from the internet). It contains the safety instructions, hints 
and technical data to be observed during installation. Subject to change with-
out notice.

 Caution

In order to ensure reliable functioning of this product, take care to transport, 
store, position and mount it appropriately. Exercise care when you operate and 
maintain the device. Only properly qualified personnel is authorized to install 
and operate this product.

Safety information

It is important for safety reasons that you read and understand the below 
instructions before you install the system:

• 

Installation, connection, commissioning and maintenance shall be done by 
properly qualified personnel.

• 

It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of 
the User information.

• 

It is the responsibility of the customer to ensure that the electronic display 
is correctly connected and configured.

• 

Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.

Mounting of the electronic display

For panel mounting we recommend the following dimensions:

 69 

 49 

 35 

 74 

 ≤R

for screw M3

Mounting of the magnetic sensor

The sensor senses the incremental travel information of the MB500/1 magnetic 
tape.

The magnetic sensor, L versions, is mounted by means of the two attached 
screws via the ø3.5 mm through holes. Fastening torque = 0.25 Nm.

Mounting the magnetic tape

Stick the magnetic tape level to the mounting surface or the distance to be 
measured. Unevenness impairs measuring accuracy.

Mounting steps:

• 

Clean mounting surface 

1

 carefully.

• 

Remove protective film 

2

 of the adhesive tape 

3

.

• 

Stick down the magnetic tape 

4

.

• 

Clean surface of magnetic tape carefully.

• 

Remove protective film 

6

 of the cover tape 

5

.

• 

Fix cover tape (both ends should slightly overlap).

• 

Also fix cover tape's ends to avoid unintentional peeling.

5

1

2

3

4

6

 Notice!

The tolerance and gap measures must be observed over the whole measuring 
length.

  

  

  

  

0.

1 ... 2 mm

Gap sensor/magnetic strip

<1°

<3°

active side

Maximum alignment error

<3°

Direction of 
outgoing cable

PE-connection (cable shoe 
for M3 only with sensor 
cable length >0.3 m)

Travel direction
positive counting direction

±2 mm

  

  

  

Travel direction
positive counting 
direction

0.

1 ... 1.5 mm

≤1 mm

≤30°

active side

Electrical Installation

The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the electronic display or the connection lines!

• 

When mounting the system keep a maximum possible distance from lines 
loaded with interference. Use screening shields or metallized housings.

Connection of power supply

By an internal Battery powered.

 Caution

As soon as the battery voltage falls below a defined value, this will be signalled 
by a symbol on the display. On this stage, the functioning of the electronic dis-
play is ensured for a limited time. However, the battery should be replaced by 
SIKO as soon as possible.